土壤电离对水平接地电极感应瞬态电流的影响

S. Šesnić, D. Poljak, Goran Knezic
{"title":"土壤电离对水平接地电极感应瞬态电流的影响","authors":"S. Šesnić, D. Poljak, Goran Knezic","doi":"10.1109/SOFTCOM.2015.7314100","DOIUrl":null,"url":null,"abstract":"The paper deals with the assessment of the influence of soil ionization on the transient current induced along the horizontal grounding electrode. Transient response of the grounding electrode buried in a lossy half-space is determined via the analytical solution of the corresponding Pocklington equation in the time domain. The electrode is excited by an equivalent current source representing the lightning strike current. Presence of the earth-air interface is taken into account via simplified reflection coefficient arising from the Modified Image Theory (MIT). The influence of the soil ionization is taken into account as an increase of soil conductivity when critical value of the electric field is exceeded in the vicinity of the electrode. The calculations have been performed for different steady-state conductivities of the soil, various electrode lengths and different types of lightning strikes. The results for the transient current have been compared to the results obtained by calculation without influence of soil ionization.","PeriodicalId":264787,"journal":{"name":"2015 23rd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of the soil ionization on the transient current induced along the horizontal grounding electrode\",\"authors\":\"S. Šesnić, D. Poljak, Goran Knezic\",\"doi\":\"10.1109/SOFTCOM.2015.7314100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with the assessment of the influence of soil ionization on the transient current induced along the horizontal grounding electrode. Transient response of the grounding electrode buried in a lossy half-space is determined via the analytical solution of the corresponding Pocklington equation in the time domain. The electrode is excited by an equivalent current source representing the lightning strike current. Presence of the earth-air interface is taken into account via simplified reflection coefficient arising from the Modified Image Theory (MIT). The influence of the soil ionization is taken into account as an increase of soil conductivity when critical value of the electric field is exceeded in the vicinity of the electrode. The calculations have been performed for different steady-state conductivities of the soil, various electrode lengths and different types of lightning strikes. The results for the transient current have been compared to the results obtained by calculation without influence of soil ionization.\",\"PeriodicalId\":264787,\"journal\":{\"name\":\"2015 23rd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 23rd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SOFTCOM.2015.7314100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 23rd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SOFTCOM.2015.7314100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文讨论了土壤电离对水平接地电极产生的瞬态电流的影响。通过波克林顿方程在时域上的解析解,确定了埋在有耗半空间中的接地电极的瞬态响应。电极由代表雷击电流的等效电流源激发。通过修正像理论(MIT)产生的简化反射系数考虑了地空界面的存在。土壤电离的影响被考虑为当电场的临界值在电极附近超过时土壤电导率的增加。对土壤的不同稳态电导率、不同电极长度和不同雷击类型进行了计算。并将暂态电流的计算结果与不受土壤电离影响的计算结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of the soil ionization on the transient current induced along the horizontal grounding electrode
The paper deals with the assessment of the influence of soil ionization on the transient current induced along the horizontal grounding electrode. Transient response of the grounding electrode buried in a lossy half-space is determined via the analytical solution of the corresponding Pocklington equation in the time domain. The electrode is excited by an equivalent current source representing the lightning strike current. Presence of the earth-air interface is taken into account via simplified reflection coefficient arising from the Modified Image Theory (MIT). The influence of the soil ionization is taken into account as an increase of soil conductivity when critical value of the electric field is exceeded in the vicinity of the electrode. The calculations have been performed for different steady-state conductivities of the soil, various electrode lengths and different types of lightning strikes. The results for the transient current have been compared to the results obtained by calculation without influence of soil ionization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信