{"title":"结合DVR和UPS技术提高敏感电器供电可靠性的新概念","authors":"B. Dobrucký, J. Šedo, P. Braciník, M. Lusková","doi":"10.1109/ELEKTRO49696.2020.9130327","DOIUrl":null,"url":null,"abstract":"The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.","PeriodicalId":165069,"journal":{"name":"2020 ELEKTRO","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving reliability of sensitive appliance supply combining DVR and UPS techniques: A new concept\",\"authors\":\"B. Dobrucký, J. Šedo, P. Braciník, M. Lusková\",\"doi\":\"10.1109/ELEKTRO49696.2020.9130327\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.\",\"PeriodicalId\":165069,\"journal\":{\"name\":\"2020 ELEKTRO\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 ELEKTRO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELEKTRO49696.2020.9130327\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 ELEKTRO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELEKTRO49696.2020.9130327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improving reliability of sensitive appliance supply combining DVR and UPS techniques: A new concept
The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.