结合DVR和UPS技术提高敏感电器供电可靠性的新概念

B. Dobrucký, J. Šedo, P. Braciník, M. Lusková
{"title":"结合DVR和UPS技术提高敏感电器供电可靠性的新概念","authors":"B. Dobrucký, J. Šedo, P. Braciník, M. Lusková","doi":"10.1109/ELEKTRO49696.2020.9130327","DOIUrl":null,"url":null,"abstract":"The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.","PeriodicalId":165069,"journal":{"name":"2020 ELEKTRO","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving reliability of sensitive appliance supply combining DVR and UPS techniques: A new concept\",\"authors\":\"B. Dobrucký, J. Šedo, P. Braciník, M. Lusková\",\"doi\":\"10.1109/ELEKTRO49696.2020.9130327\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.\",\"PeriodicalId\":165069,\"journal\":{\"name\":\"2020 ELEKTRO\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 ELEKTRO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELEKTRO49696.2020.9130327\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 ELEKTRO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELEKTRO49696.2020.9130327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究的是如何改进交流网络中相敏电器的安全供电。主要是在电源电压不改变相位的情况下,处理输送能量的短时波动或非线性负载对供电网络的影响[1]-[4]。动态电压恢复器(DVR)与不间断电源(UPS)相结合的技术使电压跌落补偿成为可能。这需要一种快速的控制方法,可以在几个/几个计算步骤中为相敏负载提供电压恢复,因此,使用死拍调节器。文中给出了无补偿控制和带补偿控制的Matlab/Simulink仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving reliability of sensitive appliance supply combining DVR and UPS techniques: A new concept
The paper is about improving a secure supply of phase-sensitive appliances in the AC network. Mainly, it deals with short-time sags of energy delivering or/and influence of non-linear loads on the power supply network [1]–[4] without a change of a phase position of the supply voltage. Application of combine techniques of dynamical voltage restorer (DVR) and uninterruptible power supply (UPS) makes possible the voltage sags compensation. This needs a fast control method which can provide a voltage recovery for phase-sensitive loads during a few/several calculation steps, so, the dead-beat regulator is used. The simulation results in Matlab/Simulink without and with compensation control are given in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信