{"title":"背靠背变换器单周期控制的数字实现","authors":"G. Petrone, M. Vitelli, G. Spagnuolo","doi":"10.1109/PEDG.2012.6254024","DOIUrl":null,"url":null,"abstract":"In this paper a simple digital implementation of one cycle control for the driving of a bidirectional three-phase back-to-back inverter is discussed. Such a digital implementation has been simulated in both grid-connected and stand alone configuration and the achieved performances have been compared with the corresponding ones obtained by adopting the standard analog implementation of one cycle control. The digital version preserves the same dynamic performances of the analog one even in presence of abrupt variations in the input current and during the transitions from grid-connected to stand-alone operating mode. The simulation results allow to assess the validity and the applicability of the proposed digital architecture in low cost microcontroller.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Digital implementation of one cycle control in back to back converters\",\"authors\":\"G. Petrone, M. Vitelli, G. Spagnuolo\",\"doi\":\"10.1109/PEDG.2012.6254024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a simple digital implementation of one cycle control for the driving of a bidirectional three-phase back-to-back inverter is discussed. Such a digital implementation has been simulated in both grid-connected and stand alone configuration and the achieved performances have been compared with the corresponding ones obtained by adopting the standard analog implementation of one cycle control. The digital version preserves the same dynamic performances of the analog one even in presence of abrupt variations in the input current and during the transitions from grid-connected to stand-alone operating mode. The simulation results allow to assess the validity and the applicability of the proposed digital architecture in low cost microcontroller.\",\"PeriodicalId\":146438,\"journal\":{\"name\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDG.2012.6254024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文讨论了一种用于驱动双向三相背靠背逆变器的单周期控制的简单数字实现。对该数字实现在并网和独立配置下进行了仿真,并与采用单周期控制的标准模拟实现所获得的相应性能进行了比较。即使在输入电流突然变化以及从并网到独立工作模式的过渡期间,数字版本也保留了模拟版本相同的动态性能。仿真结果可以评估所提出的数字架构在低成本微控制器中的有效性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Digital implementation of one cycle control in back to back converters
In this paper a simple digital implementation of one cycle control for the driving of a bidirectional three-phase back-to-back inverter is discussed. Such a digital implementation has been simulated in both grid-connected and stand alone configuration and the achieved performances have been compared with the corresponding ones obtained by adopting the standard analog implementation of one cycle control. The digital version preserves the same dynamic performances of the analog one even in presence of abrupt variations in the input current and during the transitions from grid-connected to stand-alone operating mode. The simulation results allow to assess the validity and the applicability of the proposed digital architecture in low cost microcontroller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信