{"title":"非对称电压跌落情况下uvrt -容器与中压网格模拟器的阻抗特性比较","authors":"S. Azarian, T. Jersch, S. Khan","doi":"10.1109/CWD.2019.8679528","DOIUrl":null,"url":null,"abstract":"1This paper presents the concept of electrical testing, such as under voltage ride through (UVRT) of wind turbines on test bench using Power Electronics Grid Simula-tor (PEGS). PEGS can emulate an artificial medium voltage grid up to 36kV. One of the PEGS capabilities is to add artificial series impedance to the voltage source in fa-vor of changing the virtual short circuit power at the point of common coupling (PCC). In order to verify the test bench UVRT tests it is essential to show if PEGS is capable to emulate same grid behavior and characteristics as UVRT-Container. Later, a com-parison of the simulation results of the developed PEGS test to the UVRT-Container test is presented. In case of a two-phase fault emulated by UVRT-Container, the im-pedance seen by the faulted and un-faulted phases are changed during the fault due to additional short circuit impedance connected to the grid. The aim of this paper is to show that the PEGS can emulate the impedance for each phase during unsymmet-rical faults.","PeriodicalId":173647,"journal":{"name":"2019 Conference for Wind Power Drives (CWD)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Comparison of impedance behavior of UVRT-Container with medium voltage grid simulator in case of unsymmetrical voltage dip\",\"authors\":\"S. Azarian, T. Jersch, S. Khan\",\"doi\":\"10.1109/CWD.2019.8679528\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"1This paper presents the concept of electrical testing, such as under voltage ride through (UVRT) of wind turbines on test bench using Power Electronics Grid Simula-tor (PEGS). PEGS can emulate an artificial medium voltage grid up to 36kV. One of the PEGS capabilities is to add artificial series impedance to the voltage source in fa-vor of changing the virtual short circuit power at the point of common coupling (PCC). In order to verify the test bench UVRT tests it is essential to show if PEGS is capable to emulate same grid behavior and characteristics as UVRT-Container. Later, a com-parison of the simulation results of the developed PEGS test to the UVRT-Container test is presented. In case of a two-phase fault emulated by UVRT-Container, the im-pedance seen by the faulted and un-faulted phases are changed during the fault due to additional short circuit impedance connected to the grid. The aim of this paper is to show that the PEGS can emulate the impedance for each phase during unsymmet-rical faults.\",\"PeriodicalId\":173647,\"journal\":{\"name\":\"2019 Conference for Wind Power Drives (CWD)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Conference for Wind Power Drives (CWD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CWD.2019.8679528\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Conference for Wind Power Drives (CWD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CWD.2019.8679528","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了利用电力电子电网仿真软件(PEGS)在试验台上对风力发电机组进行欠压穿越(UVRT)等电气测试的概念。PEGS可以模拟高达36kV的人工中压电网。PEGS的功能之一是在电压源上添加人工串联阻抗,以改变共耦合点(PCC)的虚拟短路功率。为了验证测试台架UVRT测试,必须显示PEGS是否能够模拟与UVRT- container相同的网格行为和特征。最后,将所开发的PEGS测试与UVRT-Container测试的仿真结果进行了比较。在UVRT-Container模拟的两相故障中,由于连接到电网的额外短路阻抗,故障期间故障相和未故障相所看到的阻抗发生了变化。本文的目的是证明PEGS可以模拟非对称故障时各相位的阻抗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of impedance behavior of UVRT-Container with medium voltage grid simulator in case of unsymmetrical voltage dip
1This paper presents the concept of electrical testing, such as under voltage ride through (UVRT) of wind turbines on test bench using Power Electronics Grid Simula-tor (PEGS). PEGS can emulate an artificial medium voltage grid up to 36kV. One of the PEGS capabilities is to add artificial series impedance to the voltage source in fa-vor of changing the virtual short circuit power at the point of common coupling (PCC). In order to verify the test bench UVRT tests it is essential to show if PEGS is capable to emulate same grid behavior and characteristics as UVRT-Container. Later, a com-parison of the simulation results of the developed PEGS test to the UVRT-Container test is presented. In case of a two-phase fault emulated by UVRT-Container, the im-pedance seen by the faulted and un-faulted phases are changed during the fault due to additional short circuit impedance connected to the grid. The aim of this paper is to show that the PEGS can emulate the impedance for each phase during unsymmet-rical faults.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信