电容电流的开关

E. Dullni, D. Gentsch, I. Kleberg, K. Niayesh, W. Shang
{"title":"电容电流的开关","authors":"E. Dullni, D. Gentsch, I. Kleberg, K. Niayesh, W. Shang","doi":"10.1109/DEIV.2004.1422633","DOIUrl":null,"url":null,"abstract":"The new IEC 62271-100 requires an extensive proof of the capability of capacitive switching for a breaker under test. For vacuum circuit breakers. dielectric properties are mainly determined by the condition of the contact surfaces, which are modified by in-rush currents as well as load-breaking currents. A synthetic single-phase test device has been erected in order to investigate these dependencies in detail and to get knowledge of the statistical properties of the investigated interrupters. The results are evaluated with respect to pre-ignition field strengths and contact strokes. Application to commercial solutions are presented coping with the required standard class C2.","PeriodicalId":137370,"journal":{"name":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Switching of capacitive currents\",\"authors\":\"E. Dullni, D. Gentsch, I. Kleberg, K. Niayesh, W. Shang\",\"doi\":\"10.1109/DEIV.2004.1422633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The new IEC 62271-100 requires an extensive proof of the capability of capacitive switching for a breaker under test. For vacuum circuit breakers. dielectric properties are mainly determined by the condition of the contact surfaces, which are modified by in-rush currents as well as load-breaking currents. A synthetic single-phase test device has been erected in order to investigate these dependencies in detail and to get knowledge of the statistical properties of the investigated interrupters. The results are evaluated with respect to pre-ignition field strengths and contact strokes. Application to commercial solutions are presented coping with the required standard class C2.\",\"PeriodicalId\":137370,\"journal\":{\"name\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2004.1422633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2004.1422633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

新的IEC 62271-100要求对被测断路器的容性开关能力进行广泛的证明。用于真空断路器。介质的介电性能主要取决于接触表面的状况,而接触表面的状况会受到冲击电流和负载断开电流的影响。为了详细研究这些依赖关系,并了解所研究的断流器的统计特性,建立了一个综合单相试验装置。根据预点火场强和接触冲程对结果进行了评价。应用于商业解决方案,以满足所需的标准等级C2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Switching of capacitive currents
The new IEC 62271-100 requires an extensive proof of the capability of capacitive switching for a breaker under test. For vacuum circuit breakers. dielectric properties are mainly determined by the condition of the contact surfaces, which are modified by in-rush currents as well as load-breaking currents. A synthetic single-phase test device has been erected in order to investigate these dependencies in detail and to get knowledge of the statistical properties of the investigated interrupters. The results are evaluated with respect to pre-ignition field strengths and contact strokes. Application to commercial solutions are presented coping with the required standard class C2.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信