高压输电线路附近电磁环境评价的矩量法

Yong Cheng, W. Cao
{"title":"高压输电线路附近电磁环境评价的矩量法","authors":"Yong Cheng, W. Cao","doi":"10.1109/CEEM.2000.853927","DOIUrl":null,"url":null,"abstract":"A moment method analysis is presented in this paper for computing the electrical field intensity in the surrounding space of a high-voltage multiconductor transmission line above the ground. In this analysis, the number of conductors, and the shape of cross-section of lines are assumed to be arbitrary. As a result, this formulation and its corresponding computer program would be applicable to the assessment of electromagnetic pollution produced by a high-voltage multiconductor transmission line system and may be used in calculation of interference between power system and telecommunication lines as well. The computed results are compared with those obtained by using an analytical approach and a good agreement between the two results justifies the correctness and effectiveness of this method.","PeriodicalId":153945,"journal":{"name":"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A method-of-moments approach to EM environment assessment nearby high-voltage transmission lines\",\"authors\":\"Yong Cheng, W. Cao\",\"doi\":\"10.1109/CEEM.2000.853927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A moment method analysis is presented in this paper for computing the electrical field intensity in the surrounding space of a high-voltage multiconductor transmission line above the ground. In this analysis, the number of conductors, and the shape of cross-section of lines are assumed to be arbitrary. As a result, this formulation and its corresponding computer program would be applicable to the assessment of electromagnetic pollution produced by a high-voltage multiconductor transmission line system and may be used in calculation of interference between power system and telecommunication lines as well. The computed results are compared with those obtained by using an analytical approach and a good agreement between the two results justifies the correctness and effectiveness of this method.\",\"PeriodicalId\":153945,\"journal\":{\"name\":\"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEEM.2000.853927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEM.2000.853927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种矩量法分析方法,用于计算地面上高压多导体输电线路周围空间的电场强度。在这个分析中,假设导体的数目和导线截面的形状是任意的。因此,该公式及其相应的计算机程序适用于高压多导体传输线系统产生的电磁污染的评估,也可用于电力系统与通信线路之间干扰的计算。将计算结果与解析法计算结果进行了比较,两者吻合较好,证明了该方法的正确性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A method-of-moments approach to EM environment assessment nearby high-voltage transmission lines
A moment method analysis is presented in this paper for computing the electrical field intensity in the surrounding space of a high-voltage multiconductor transmission line above the ground. In this analysis, the number of conductors, and the shape of cross-section of lines are assumed to be arbitrary. As a result, this formulation and its corresponding computer program would be applicable to the assessment of electromagnetic pollution produced by a high-voltage multiconductor transmission line system and may be used in calculation of interference between power system and telecommunication lines as well. The computed results are compared with those obtained by using an analytical approach and a good agreement between the two results justifies the correctness and effectiveness of this method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信