{"title":"安装同步冷凝器的高压直流接收端发生故障时逆变器的动态特性研究","authors":"L. Luo, Tao Pang","doi":"10.1109/APPEEC50844.2021.9687711","DOIUrl":null,"url":null,"abstract":"High voltage direct current (HVDC) is more and more widely used in the world. Its grid connection brings stability problems to the traditional AC power grid. As a common fault of HVDC, commutation failure usually occurs at the receiving end. In this paper, the typical circuit structure and control strategy of HVDC are used to analyze the dynamic characteristics of inverter to AC side fault of receiving end under different transmission power, and the influence of Synchronous condenser (SC) and filter compensation device (FC) on AC side fault of receiving end is analyzed. Finally, based on the parameters of Jiuquan Hunan HVDC transmission project, the correctness of the analysis is verified by simulation on PSCAD / EMTDC.","PeriodicalId":345537,"journal":{"name":"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on dynamic characteristics of inverter when fault occurs in HVDC receiving end equipped with synchronous condenser\",\"authors\":\"L. Luo, Tao Pang\",\"doi\":\"10.1109/APPEEC50844.2021.9687711\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage direct current (HVDC) is more and more widely used in the world. Its grid connection brings stability problems to the traditional AC power grid. As a common fault of HVDC, commutation failure usually occurs at the receiving end. In this paper, the typical circuit structure and control strategy of HVDC are used to analyze the dynamic characteristics of inverter to AC side fault of receiving end under different transmission power, and the influence of Synchronous condenser (SC) and filter compensation device (FC) on AC side fault of receiving end is analyzed. Finally, based on the parameters of Jiuquan Hunan HVDC transmission project, the correctness of the analysis is verified by simulation on PSCAD / EMTDC.\",\"PeriodicalId\":345537,\"journal\":{\"name\":\"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)\",\"volume\":\"241 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC50844.2021.9687711\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC50844.2021.9687711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on dynamic characteristics of inverter when fault occurs in HVDC receiving end equipped with synchronous condenser
High voltage direct current (HVDC) is more and more widely used in the world. Its grid connection brings stability problems to the traditional AC power grid. As a common fault of HVDC, commutation failure usually occurs at the receiving end. In this paper, the typical circuit structure and control strategy of HVDC are used to analyze the dynamic characteristics of inverter to AC side fault of receiving end under different transmission power, and the influence of Synchronous condenser (SC) and filter compensation device (FC) on AC side fault of receiving end is analyzed. Finally, based on the parameters of Jiuquan Hunan HVDC transmission project, the correctness of the analysis is verified by simulation on PSCAD / EMTDC.