一种基于全息谱的非实接地网络故障选线算法

Daoyang Yu, Fan Zhou, Xing Jin, Guanghua Xu
{"title":"一种基于全息谱的非实接地网络故障选线算法","authors":"Daoyang Yu, Fan Zhou, Xing Jin, Guanghua Xu","doi":"10.1109/POWERCON.2010.5666442","DOIUrl":null,"url":null,"abstract":"The methods of line selection today focus on one target of the signal such as amplitude, frequency or phase. A novel method based on holospectrum algorithm to detect single-phase faults in distribution systems is proposed in this paper. After structuring analytic signals of zero sequence current and voltage, the holospectrum algorithm is applied. Thus the analysis of combined signal of amplitude, frequency and phase is realized. Compared with the use of single amplitude, frequency or phase, combined signal carries more details and information of transient signal. Theoretical analysis and simulation based on Simulink of MATLAB show that the presented method can exactly and effectively choose the faulty line in single-phase-to-ground fault.","PeriodicalId":169553,"journal":{"name":"2010 International Conference on Power System Technology","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A fault line selection algorithm in non-solidly earthed network based on holospectrum\",\"authors\":\"Daoyang Yu, Fan Zhou, Xing Jin, Guanghua Xu\",\"doi\":\"10.1109/POWERCON.2010.5666442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The methods of line selection today focus on one target of the signal such as amplitude, frequency or phase. A novel method based on holospectrum algorithm to detect single-phase faults in distribution systems is proposed in this paper. After structuring analytic signals of zero sequence current and voltage, the holospectrum algorithm is applied. Thus the analysis of combined signal of amplitude, frequency and phase is realized. Compared with the use of single amplitude, frequency or phase, combined signal carries more details and information of transient signal. Theoretical analysis and simulation based on Simulink of MATLAB show that the presented method can exactly and effectively choose the faulty line in single-phase-to-ground fault.\",\"PeriodicalId\":169553,\"journal\":{\"name\":\"2010 International Conference on Power System Technology\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Power System Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2010.5666442\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2010.5666442","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前的选线方法集中于信号的一个目标,如幅度、频率或相位。提出了一种基于全谱算法的配电系统单相故障检测新方法。在构造零序电流和电压解析信号后,应用全谱算法。从而实现了对幅值、频率和相位组合信号的分析。与单幅、单频或单相相比,组合信号携带了更多的瞬态信号的细节和信息。理论分析和基于MATLAB的Simulink仿真表明,该方法能够准确有效地选择单相接地故障的故障线路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A fault line selection algorithm in non-solidly earthed network based on holospectrum
The methods of line selection today focus on one target of the signal such as amplitude, frequency or phase. A novel method based on holospectrum algorithm to detect single-phase faults in distribution systems is proposed in this paper. After structuring analytic signals of zero sequence current and voltage, the holospectrum algorithm is applied. Thus the analysis of combined signal of amplitude, frequency and phase is realized. Compared with the use of single amplitude, frequency or phase, combined signal carries more details and information of transient signal. Theoretical analysis and simulation based on Simulink of MATLAB show that the presented method can exactly and effectively choose the faulty line in single-phase-to-ground fault.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信