K. Kimura, S. Ushirone, T. Fukushima, S. Ohtsuka, M. Hikita
{"title":"长时间重复双极脉冲作用下双绞线样品的局部放电起始电压","authors":"K. Kimura, S. Ushirone, T. Fukushima, S. Ohtsuka, M. Hikita","doi":"10.1109/ELINSL.2004.1380514","DOIUrl":null,"url":null,"abstract":"The reliability of inverter-fed motors depends on partial discharge (PD) behavior of stator windings. In this paper we discuss partial discharge inception voltage (PDFV) characteristics of twisted-pair samples under long-time repetitive impulses using optical and electrical PD detection methods. For PDIV measurement, we adopted step-by-step and continuous rise of peak voltage of impulse. The repetitive frequency is 500 Hz. The result suggests that PD can occur even after a long period of time of repetitive impulses. We discuss practical importance of test procedure of PDIV under the special voltage waveforms.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Partial discharge inception voltage of twisted pair samples under long-time repetitive bipolar impulses\",\"authors\":\"K. Kimura, S. Ushirone, T. Fukushima, S. Ohtsuka, M. Hikita\",\"doi\":\"10.1109/ELINSL.2004.1380514\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reliability of inverter-fed motors depends on partial discharge (PD) behavior of stator windings. In this paper we discuss partial discharge inception voltage (PDFV) characteristics of twisted-pair samples under long-time repetitive impulses using optical and electrical PD detection methods. For PDIV measurement, we adopted step-by-step and continuous rise of peak voltage of impulse. The repetitive frequency is 500 Hz. The result suggests that PD can occur even after a long period of time of repetitive impulses. We discuss practical importance of test procedure of PDIV under the special voltage waveforms.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380514\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Partial discharge inception voltage of twisted pair samples under long-time repetitive bipolar impulses
The reliability of inverter-fed motors depends on partial discharge (PD) behavior of stator windings. In this paper we discuss partial discharge inception voltage (PDFV) characteristics of twisted-pair samples under long-time repetitive impulses using optical and electrical PD detection methods. For PDIV measurement, we adopted step-by-step and continuous rise of peak voltage of impulse. The repetitive frequency is 500 Hz. The result suggests that PD can occur even after a long period of time of repetitive impulses. We discuss practical importance of test procedure of PDIV under the special voltage waveforms.