{"title":"脉冲负载高压直流电源的平均电流模式控制","authors":"N. Vishwanathan, V. Ramanarayanan","doi":"10.1109/IAS.2002.1042711","DOIUrl":null,"url":null,"abstract":"High voltage power supplies with pulse load (125 kHz and 10 % duty cycle) are investigated which are of interest for applications like radar power supplies with an output voltage of 22 kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation (<0.01 %) and high efficiency (>85 %). This paper proposes a methodology to tackle the problems associated with this type of application. A phase-modulated series resonant converter with ZVS is used as the power converter. Average value of the rectified tank current is controlled to regulate the output voltage. Synchronization of converter switching with load pulses enables the converter to switch at half the load switching frequency. Low switching frequency helps in ensuring safety of HV transformer insulation and reduction of losses due to skin & proximity effect. Average current mode control gives excellent dynamic response with simple closed loop design.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Average current mode control of high voltage DC power supply for pulsed load application\",\"authors\":\"N. Vishwanathan, V. Ramanarayanan\",\"doi\":\"10.1109/IAS.2002.1042711\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage power supplies with pulse load (125 kHz and 10 % duty cycle) are investigated which are of interest for applications like radar power supplies with an output voltage of 22 kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation (<0.01 %) and high efficiency (>85 %). This paper proposes a methodology to tackle the problems associated with this type of application. A phase-modulated series resonant converter with ZVS is used as the power converter. Average value of the rectified tank current is controlled to regulate the output voltage. Synchronization of converter switching with load pulses enables the converter to switch at half the load switching frequency. Low switching frequency helps in ensuring safety of HV transformer insulation and reduction of losses due to skin & proximity effect. Average current mode control gives excellent dynamic response with simple closed loop design.\",\"PeriodicalId\":202482,\"journal\":{\"name\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2002.1042711\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1042711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

研究了具有脉冲负载(125 kHz和10%占空比)的高压电源,这些电源对输出电压为22 kV的雷达电源等应用感兴趣。该类型电源的性能规格非常严格,要求严格调节(85%)。本文提出了一种方法来解决与这类应用程序相关的问题。采用带ZVS的调相串联谐振变换器作为功率变换器。通过控制整流槽电流的平均值来调节输出电压。变流器开关与负载脉冲同步,使变流器以一半的负载开关频率开关。低开关频率有助于确保高压变压器绝缘的安全性,减少因趋肤效应和接近效应造成的损耗。平均电流模式控制采用简单的闭环设计,具有良好的动态响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Average current mode control of high voltage DC power supply for pulsed load application
High voltage power supplies with pulse load (125 kHz and 10 % duty cycle) are investigated which are of interest for applications like radar power supplies with an output voltage of 22 kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation (<0.01 %) and high efficiency (>85 %). This paper proposes a methodology to tackle the problems associated with this type of application. A phase-modulated series resonant converter with ZVS is used as the power converter. Average value of the rectified tank current is controlled to regulate the output voltage. Synchronization of converter switching with load pulses enables the converter to switch at half the load switching frequency. Low switching frequency helps in ensuring safety of HV transformer insulation and reduction of losses due to skin & proximity effect. Average current mode control gives excellent dynamic response with simple closed loop design.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信