静态同步串联补偿器存在时距离继电器故障状态下的误动作

A. Purohit, V. Gohokar
{"title":"静态同步串联补偿器存在时距离继电器故障状态下的误动作","authors":"A. Purohit, V. Gohokar","doi":"10.1109/ICPEA.2019.8818520","DOIUrl":null,"url":null,"abstract":"With the advent of technology, Flexible AC Transmission Systems (FACTS) are popularly used to increase the power transmission capacity of transmission lines and for optimum utilization of power system capability which result into the substantial change in system dynamics. Change in system dynamics has an impact on protection of power system as there is drastic change in the net impedance of transmission line due to FACTS devices which gives rise to over-reaching or under-reaching problem in distance protection scheme. In this paper, performance of distance relay in the presence of Static Synchronous Series Compensator (SSSC) is studied under various fault conditions. A 400kV, 300km transmission line is designed and simulated using MATLAB/SIMULINK software and results are presented to show influence of SSSC on mho characteristic of distance relay.","PeriodicalId":427328,"journal":{"name":"2019 IEEE 2nd International Conference on Power and Energy Applications (ICPEA)","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Maloperation of Distance Relay under Faulty Conditions in presence of Static Synchronous Series Compensator\",\"authors\":\"A. Purohit, V. Gohokar\",\"doi\":\"10.1109/ICPEA.2019.8818520\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the advent of technology, Flexible AC Transmission Systems (FACTS) are popularly used to increase the power transmission capacity of transmission lines and for optimum utilization of power system capability which result into the substantial change in system dynamics. Change in system dynamics has an impact on protection of power system as there is drastic change in the net impedance of transmission line due to FACTS devices which gives rise to over-reaching or under-reaching problem in distance protection scheme. In this paper, performance of distance relay in the presence of Static Synchronous Series Compensator (SSSC) is studied under various fault conditions. A 400kV, 300km transmission line is designed and simulated using MATLAB/SIMULINK software and results are presented to show influence of SSSC on mho characteristic of distance relay.\",\"PeriodicalId\":427328,\"journal\":{\"name\":\"2019 IEEE 2nd International Conference on Power and Energy Applications (ICPEA)\",\"volume\":\"134 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 2nd International Conference on Power and Energy Applications (ICPEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEA.2019.8818520\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 2nd International Conference on Power and Energy Applications (ICPEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEA.2019.8818520","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

随着技术的发展,柔性交流输电系统(FACTS)被广泛用于提高输电线路的输电能力和优化利用电力系统的能力,从而导致系统动力学的重大变化。系统动力学的变化会对电力系统的保护产生影响,因为FACTS器件会使输电线路的净阻抗发生剧烈变化,从而导致距离保护方案出现过伸或欠伸问题。本文研究了静态同步串联补偿器(SSSC)存在时距离继电器在各种故障条件下的性能。利用MATLAB/SIMULINK软件对400kV、300km的输电线路进行了设计和仿真,分析了SSSC对距离继电器mho特性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Maloperation of Distance Relay under Faulty Conditions in presence of Static Synchronous Series Compensator
With the advent of technology, Flexible AC Transmission Systems (FACTS) are popularly used to increase the power transmission capacity of transmission lines and for optimum utilization of power system capability which result into the substantial change in system dynamics. Change in system dynamics has an impact on protection of power system as there is drastic change in the net impedance of transmission line due to FACTS devices which gives rise to over-reaching or under-reaching problem in distance protection scheme. In this paper, performance of distance relay in the presence of Static Synchronous Series Compensator (SSSC) is studied under various fault conditions. A 400kV, 300km transmission line is designed and simulated using MATLAB/SIMULINK software and results are presented to show influence of SSSC on mho characteristic of distance relay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信