{"title":"采用隔离式异步发电机的小型水力发电集成固态控制器","authors":"Bhim Singh, V. Rajagopal","doi":"10.1109/ICPCES.2010.5698694","DOIUrl":null,"url":null,"abstract":"This paper deals with an integrated solid state controller (ISSC) for an isolated asynchronous generator (IAG) used in small hydro power generation for feeding three-phase four-wire loads. The proposed ISSC is used to control the voltage and frequency of IAG. This ISSC is realized using a three-leg insulated gate bipolar transistors (IGBTs) based current controlled voltage source converter (CC-VSC), a star-hexagon transformer, a capacitor, a chopper switch and an auxiliary load on its dc bus. The proposed ISSC for an isolated generating system is modeled and simulated in MATLAB along with Simulink and simpower system (SPS) blockset toolboxes. The simulated results of IAG-ISSC system are presented to demonstrate its performance for feeding three-phase four-wire loads with the neutral current compensation.","PeriodicalId":439893,"journal":{"name":"2010 International Conference on Power, Control and Embedded Systems","volume":"173 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Integrated solid state controller for small hydro generation using isolated asynchronous generator\",\"authors\":\"Bhim Singh, V. Rajagopal\",\"doi\":\"10.1109/ICPCES.2010.5698694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with an integrated solid state controller (ISSC) for an isolated asynchronous generator (IAG) used in small hydro power generation for feeding three-phase four-wire loads. The proposed ISSC is used to control the voltage and frequency of IAG. This ISSC is realized using a three-leg insulated gate bipolar transistors (IGBTs) based current controlled voltage source converter (CC-VSC), a star-hexagon transformer, a capacitor, a chopper switch and an auxiliary load on its dc bus. The proposed ISSC for an isolated generating system is modeled and simulated in MATLAB along with Simulink and simpower system (SPS) blockset toolboxes. The simulated results of IAG-ISSC system are presented to demonstrate its performance for feeding three-phase four-wire loads with the neutral current compensation.\",\"PeriodicalId\":439893,\"journal\":{\"name\":\"2010 International Conference on Power, Control and Embedded Systems\",\"volume\":\"173 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Power, Control and Embedded Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCES.2010.5698694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Power, Control and Embedded Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCES.2010.5698694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Integrated solid state controller for small hydro generation using isolated asynchronous generator
This paper deals with an integrated solid state controller (ISSC) for an isolated asynchronous generator (IAG) used in small hydro power generation for feeding three-phase four-wire loads. The proposed ISSC is used to control the voltage and frequency of IAG. This ISSC is realized using a three-leg insulated gate bipolar transistors (IGBTs) based current controlled voltage source converter (CC-VSC), a star-hexagon transformer, a capacitor, a chopper switch and an auxiliary load on its dc bus. The proposed ISSC for an isolated generating system is modeled and simulated in MATLAB along with Simulink and simpower system (SPS) blockset toolboxes. The simulated results of IAG-ISSC system are presented to demonstrate its performance for feeding three-phase four-wire loads with the neutral current compensation.