多焦点视觉诱发电位的计算机辅助获取与统计评估

A. Cysewska-Sobusiak, A. Hulewicz, A. Grzybowski, M. Boltrukiewicz
{"title":"多焦点视觉诱发电位的计算机辅助获取与统计评估","authors":"A. Cysewska-Sobusiak, A. Hulewicz, A. Grzybowski, M. Boltrukiewicz","doi":"10.1109/VECIMS.2006.250811","DOIUrl":null,"url":null,"abstract":"The subject of this paper concerns the electro-physiological examination of the visual organ, the acquisition and statistical evaluation of the multifocal visual evoked potentials (M-VEP), in particular. The results presented are related to the real multifocal VEP waveforms, obtained during the examination of numerous patients in clinical conditions. The statistical evaluation of the results obtained during the examination of numerous healthy eyes enables the determination of electrical potential tolerance intervals and latency in the scope of the entire visual path of a healthy eye. Due to the lack of standardized values of the M-VEP test, the intervals may represent reference data in the valuation of various visual tract diseases. The data included therein, upon being exported to Microsoft Excel, enable the calculation of the average and standard deviation, and the tolerance intervals based on them","PeriodicalId":405572,"journal":{"name":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Computer-Assisted Acquisition and Statistical Evaluation of Multifocal Visual Evoked Potentials\",\"authors\":\"A. Cysewska-Sobusiak, A. Hulewicz, A. Grzybowski, M. Boltrukiewicz\",\"doi\":\"10.1109/VECIMS.2006.250811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The subject of this paper concerns the electro-physiological examination of the visual organ, the acquisition and statistical evaluation of the multifocal visual evoked potentials (M-VEP), in particular. The results presented are related to the real multifocal VEP waveforms, obtained during the examination of numerous patients in clinical conditions. The statistical evaluation of the results obtained during the examination of numerous healthy eyes enables the determination of electrical potential tolerance intervals and latency in the scope of the entire visual path of a healthy eye. Due to the lack of standardized values of the M-VEP test, the intervals may represent reference data in the valuation of various visual tract diseases. The data included therein, upon being exported to Microsoft Excel, enable the calculation of the average and standard deviation, and the tolerance intervals based on them\",\"PeriodicalId\":405572,\"journal\":{\"name\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VECIMS.2006.250811\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VECIMS.2006.250811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文的主题涉及视觉器官的电生理检查,特别是多焦视觉诱发电位(M-VEP)的获取和统计评估。所提出的结果与实际的多焦点VEP波形有关,在临床条件下对许多患者进行检查时获得。对许多健康眼睛的检查结果进行统计评估,可以确定健康眼睛整个视觉路径范围内的电位容忍间隔和延迟。由于M-VEP测试缺乏标准化值,其间隔可作为评估各种视道疾病的参考数据。其中包含的数据导出到Microsoft Excel后,可以计算平均值和标准差,并在此基础上计算公差区间
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computer-Assisted Acquisition and Statistical Evaluation of Multifocal Visual Evoked Potentials
The subject of this paper concerns the electro-physiological examination of the visual organ, the acquisition and statistical evaluation of the multifocal visual evoked potentials (M-VEP), in particular. The results presented are related to the real multifocal VEP waveforms, obtained during the examination of numerous patients in clinical conditions. The statistical evaluation of the results obtained during the examination of numerous healthy eyes enables the determination of electrical potential tolerance intervals and latency in the scope of the entire visual path of a healthy eye. Due to the lack of standardized values of the M-VEP test, the intervals may represent reference data in the valuation of various visual tract diseases. The data included therein, upon being exported to Microsoft Excel, enable the calculation of the average and standard deviation, and the tolerance intervals based on them
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信