F. Kurokawa, K. Kajiwara, Y. Shibata, Y. Yamabe, T. Tanaka, K. Hirose
{"title":"绿色IT系统中快速响应数字峰值电流型380V DC-DC变换器的性能特性","authors":"F. Kurokawa, K. Kajiwara, Y. Shibata, Y. Yamabe, T. Tanaka, K. Hirose","doi":"10.1109/ICRERA.2012.6477253","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present performance characteristics of a quick response digital peak-current-mode 380V dc-dc converter for the green IT system. A proto-type is constructed as the digital control dc-dc converter used in the higher voltage direct current (HVDC) system for the green IT. The proto-type uses the digital peak-current-mode control to show a superior transient response. A dc power supply uses 380V in above HVDC system. The transient response of proto-type is indicated in this paper. As a result, the convergence time and undershoot of output voltage are suppressed to one half and one fourth, respectively.","PeriodicalId":239142,"journal":{"name":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Performance characteristics of quick response digital peak-current-mode 380V DC-DC converter for green IT system\",\"authors\":\"F. Kurokawa, K. Kajiwara, Y. Shibata, Y. Yamabe, T. Tanaka, K. Hirose\",\"doi\":\"10.1109/ICRERA.2012.6477253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this paper is to present performance characteristics of a quick response digital peak-current-mode 380V dc-dc converter for the green IT system. A proto-type is constructed as the digital control dc-dc converter used in the higher voltage direct current (HVDC) system for the green IT. The proto-type uses the digital peak-current-mode control to show a superior transient response. A dc power supply uses 380V in above HVDC system. The transient response of proto-type is indicated in this paper. As a result, the convergence time and undershoot of output voltage are suppressed to one half and one fourth, respectively.\",\"PeriodicalId\":239142,\"journal\":{\"name\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2012.6477253\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2012.6477253","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance characteristics of quick response digital peak-current-mode 380V DC-DC converter for green IT system
The purpose of this paper is to present performance characteristics of a quick response digital peak-current-mode 380V dc-dc converter for the green IT system. A proto-type is constructed as the digital control dc-dc converter used in the higher voltage direct current (HVDC) system for the green IT. The proto-type uses the digital peak-current-mode control to show a superior transient response. A dc power supply uses 380V in above HVDC system. The transient response of proto-type is indicated in this paper. As a result, the convergence time and undershoot of output voltage are suppressed to one half and one fourth, respectively.