塔基收发台(bts) 4脚支撑v型与支撑x型的对比分析

CI-TECH Pub Date : 2020-09-23 DOI:10.33005/ci-tech.v1i01.10
CI-TECH Upnjatim, Sumaidi
{"title":"塔基收发台(bts) 4脚支撑v型与支撑x型的对比分析","authors":"CI-TECH Upnjatim, Sumaidi","doi":"10.33005/ci-tech.v1i01.10","DOIUrl":null,"url":null,"abstract":"\n \n \n \nThis paper explains the comparison 4-foot Base Transceiver Station (BTS) towers between type v bracing and type x bracing in terms of strength and economic aspects using SAP 2000 applications. As technology develops, people's desire for good telecommunications technology is enhancement. The writer analyzes the tower with type v bracing and type x bracing using the SAP 2000 application. BTS towers are used with a height of 25 meters, width of 6 meters, length of 6 meters, height of each segment of 2.5 meters. Then analyze the strengths using the SAP 2000 application based on the TIA / EIA 1991 standard with displacement not exceeding H/200. After the SAP 2000 application is finished running, the results of the building's own weight output are used for economic comparisons. The results of type v bracing analysis obtained a displacement of 0.4 millimeters with a building own weight of 123.668 KN. The result of type x bracing analysis obtained a displacement of 0.6 millimeters with a building weight of 143,440 KN. The results of this analysis recommend the BTS tower to use type v bracing instead of using type x bracing. \n \n \n \n","PeriodicalId":265863,"journal":{"name":"CI-TECH","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COMPARATIVE ANALYSIS OF TOWER BASE TRANSCEIVER STATION (BTS) FOOT 4 BETWEEN BRACING TYPE V WITH BRACING TYPE X\",\"authors\":\"CI-TECH Upnjatim, Sumaidi\",\"doi\":\"10.33005/ci-tech.v1i01.10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n \\n \\n \\nThis paper explains the comparison 4-foot Base Transceiver Station (BTS) towers between type v bracing and type x bracing in terms of strength and economic aspects using SAP 2000 applications. As technology develops, people's desire for good telecommunications technology is enhancement. The writer analyzes the tower with type v bracing and type x bracing using the SAP 2000 application. BTS towers are used with a height of 25 meters, width of 6 meters, length of 6 meters, height of each segment of 2.5 meters. Then analyze the strengths using the SAP 2000 application based on the TIA / EIA 1991 standard with displacement not exceeding H/200. After the SAP 2000 application is finished running, the results of the building's own weight output are used for economic comparisons. The results of type v bracing analysis obtained a displacement of 0.4 millimeters with a building own weight of 123.668 KN. The result of type x bracing analysis obtained a displacement of 0.6 millimeters with a building weight of 143,440 KN. The results of this analysis recommend the BTS tower to use type v bracing instead of using type x bracing. \\n \\n \\n \\n\",\"PeriodicalId\":265863,\"journal\":{\"name\":\"CI-TECH\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CI-TECH\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33005/ci-tech.v1i01.10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CI-TECH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33005/ci-tech.v1i01.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了4英尺基站(BTS)塔架在使用SAP 2000应用程序的情况下,v型支撑和x型支撑在强度和经济方面的比较。随着科技的发展,人们对优质电信技术的需求也在不断增强。利用SAP 2000软件对v型支撑和x型支撑两种类型的塔楼进行了分析。BTS塔高25米,宽6米,长6米,每段高2.5米。然后基于TIA / EIA 1991标准,在位移不超过H/200的情况下,使用SAP 2000应用程序进行优势分析。在SAP 2000应用程序完成运行后,将使用建筑物自身重量输出的结果进行经济比较。v型支撑分析结果表明,当建筑自重为123.668 KN时,其位移为0.4 mm。x型支撑分析的结果是位移为0.6毫米,建筑重量为143,440千牛。分析结果建议BTS塔采用v型支撑代替x型支撑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
COMPARATIVE ANALYSIS OF TOWER BASE TRANSCEIVER STATION (BTS) FOOT 4 BETWEEN BRACING TYPE V WITH BRACING TYPE X
This paper explains the comparison 4-foot Base Transceiver Station (BTS) towers between type v bracing and type x bracing in terms of strength and economic aspects using SAP 2000 applications. As technology develops, people's desire for good telecommunications technology is enhancement. The writer analyzes the tower with type v bracing and type x bracing using the SAP 2000 application. BTS towers are used with a height of 25 meters, width of 6 meters, length of 6 meters, height of each segment of 2.5 meters. Then analyze the strengths using the SAP 2000 application based on the TIA / EIA 1991 standard with displacement not exceeding H/200. After the SAP 2000 application is finished running, the results of the building's own weight output are used for economic comparisons. The results of type v bracing analysis obtained a displacement of 0.4 millimeters with a building own weight of 123.668 KN. The result of type x bracing analysis obtained a displacement of 0.6 millimeters with a building weight of 143,440 KN. The results of this analysis recommend the BTS tower to use type v bracing instead of using type x bracing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信