集热器系统故障后海上风电场的暂态电压稳定性

A. Sajadi, R. Kolacinski, K. Loparo
{"title":"集热器系统故障后海上风电场的暂态电压稳定性","authors":"A. Sajadi, R. Kolacinski, K. Loparo","doi":"10.1109/PECI.2016.7459227","DOIUrl":null,"url":null,"abstract":"This work focuses on the analysis of the transient voltage stability at the point of interconnection (POI) of offshore wind farms following faults on the collector system. In particular, this study studies offshore wind farms that use an AC export system to transfer generated power onshore and investigates transient voltage stability under the influence of operating reactive power support equipment such as static VAR compensators (SVC) and active power support units such as battery storage or generation units at the POI. Operation of SVC and active power support such are widely believed to improve the stability and dynamic operation of offshore wind farms. This study, using the Great Lakes Offshore Wind Study models, determines the precise conditions under which SVC and active power support can improve the transient stability of the system following faults on the collector system.","PeriodicalId":359438,"journal":{"name":"2016 IEEE Power and Energy Conference at Illinois (PECI)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Transient voltage stability of offshore wind farms following faults on the collector system\",\"authors\":\"A. Sajadi, R. Kolacinski, K. Loparo\",\"doi\":\"10.1109/PECI.2016.7459227\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work focuses on the analysis of the transient voltage stability at the point of interconnection (POI) of offshore wind farms following faults on the collector system. In particular, this study studies offshore wind farms that use an AC export system to transfer generated power onshore and investigates transient voltage stability under the influence of operating reactive power support equipment such as static VAR compensators (SVC) and active power support units such as battery storage or generation units at the POI. Operation of SVC and active power support such are widely believed to improve the stability and dynamic operation of offshore wind farms. This study, using the Great Lakes Offshore Wind Study models, determines the precise conditions under which SVC and active power support can improve the transient stability of the system following faults on the collector system.\",\"PeriodicalId\":359438,\"journal\":{\"name\":\"2016 IEEE Power and Energy Conference at Illinois (PECI)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Power and Energy Conference at Illinois (PECI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECI.2016.7459227\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2016.7459227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文着重分析了集热器系统故障后海上风电场的暂态电压稳定性。特别地,本研究研究了使用交流输出系统将发电转移到岸上的海上风电场,并研究了在POI处运行无功支持设备(如静态无功补偿器(SVC))和有功支持单元(如电池存储或发电单元)的影响下的暂态电压稳定性。SVC和有功支持的运行被广泛认为可以提高海上风电场的稳定性和动态运行。本研究利用五大湖海上风电研究模型,确定了SVC和有功支持在集热器系统发生故障后改善系统暂态稳定性的精确条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient voltage stability of offshore wind farms following faults on the collector system
This work focuses on the analysis of the transient voltage stability at the point of interconnection (POI) of offshore wind farms following faults on the collector system. In particular, this study studies offshore wind farms that use an AC export system to transfer generated power onshore and investigates transient voltage stability under the influence of operating reactive power support equipment such as static VAR compensators (SVC) and active power support units such as battery storage or generation units at the POI. Operation of SVC and active power support such are widely believed to improve the stability and dynamic operation of offshore wind farms. This study, using the Great Lakes Offshore Wind Study models, determines the precise conditions under which SVC and active power support can improve the transient stability of the system following faults on the collector system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信