基于二维圆阵列和惯性测量单元的高性能DOA/ tom内窥镜胶囊定位与跟踪

A. Nafchi, S. Goh, S. Zekavat
{"title":"基于二维圆阵列和惯性测量单元的高性能DOA/ tom内窥镜胶囊定位与跟踪","authors":"A. Nafchi, S. Goh, S. Zekavat","doi":"10.1109/WiSEE.2013.6737560","DOIUrl":null,"url":null,"abstract":"This paper investigates the performance of Wireless Capsule Endoscopy (WCE) tracking within the irregular environment of digestion system by incorporating the Directional-of-Arrival (DOA), Time-of-Arrival (TOA) and Inertial Measurement Unit (IMU) measurements with the Extended Kalman Filter (EKF). The emitter sends a signal to the WCE, and the WCE replies the signal back to the antenna arrays. Then, the round trip TOA, and the DOA of the signals transmitted from the emitter to the WCE are measured. An EKF is designed to integrate the DOA, TOA and IMU measurements to improve the WCE localization. Simulations are conducted to investigate the EKF localization performance as a function of the number of antenna arrays and TOA estimation accuracy. The impact of IMU on the localization performance will also be studied. Simulations confirm the feasibility of the WCE tracking by integrating the DOA, TOA and IMU measurements with Kalman Filter.","PeriodicalId":127644,"journal":{"name":"IEEE International Conference on Wireless for Space and Extreme Environments","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"High performance DOA/TOA-based Endoscopy Capsule localization and tracking via 2D circular arrays and inertial measurement unit\",\"authors\":\"A. Nafchi, S. Goh, S. Zekavat\",\"doi\":\"10.1109/WiSEE.2013.6737560\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the performance of Wireless Capsule Endoscopy (WCE) tracking within the irregular environment of digestion system by incorporating the Directional-of-Arrival (DOA), Time-of-Arrival (TOA) and Inertial Measurement Unit (IMU) measurements with the Extended Kalman Filter (EKF). The emitter sends a signal to the WCE, and the WCE replies the signal back to the antenna arrays. Then, the round trip TOA, and the DOA of the signals transmitted from the emitter to the WCE are measured. An EKF is designed to integrate the DOA, TOA and IMU measurements to improve the WCE localization. Simulations are conducted to investigate the EKF localization performance as a function of the number of antenna arrays and TOA estimation accuracy. The impact of IMU on the localization performance will also be studied. Simulations confirm the feasibility of the WCE tracking by integrating the DOA, TOA and IMU measurements with Kalman Filter.\",\"PeriodicalId\":127644,\"journal\":{\"name\":\"IEEE International Conference on Wireless for Space and Extreme Environments\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE International Conference on Wireless for Space and Extreme Environments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WiSEE.2013.6737560\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Conference on Wireless for Space and Extreme Environments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WiSEE.2013.6737560","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文采用扩展卡尔曼滤波(EKF)结合到达方向(DOA)、到达时间(TOA)和惯性测量单元(IMU)测量,研究了无线胶囊内窥镜(WCE)在不规则消化系统环境下的跟踪性能。发射器向WCE发送信号,WCE将信号回复给天线阵列。然后,测量了从发射器到WCE的信号的往返TOA和DOA。EKF集成了DOA、TOA和IMU测量,提高了WCE的定位。通过仿真研究了EKF定位性能与天线阵列数和TOA估计精度的关系。本文还将研究IMU对定位性能的影响。通过仿真验证了卡尔曼滤波对DOA、TOA和IMU测量值进行综合跟踪的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High performance DOA/TOA-based Endoscopy Capsule localization and tracking via 2D circular arrays and inertial measurement unit
This paper investigates the performance of Wireless Capsule Endoscopy (WCE) tracking within the irregular environment of digestion system by incorporating the Directional-of-Arrival (DOA), Time-of-Arrival (TOA) and Inertial Measurement Unit (IMU) measurements with the Extended Kalman Filter (EKF). The emitter sends a signal to the WCE, and the WCE replies the signal back to the antenna arrays. Then, the round trip TOA, and the DOA of the signals transmitted from the emitter to the WCE are measured. An EKF is designed to integrate the DOA, TOA and IMU measurements to improve the WCE localization. Simulations are conducted to investigate the EKF localization performance as a function of the number of antenna arrays and TOA estimation accuracy. The impact of IMU on the localization performance will also be studied. Simulations confirm the feasibility of the WCE tracking by integrating the DOA, TOA and IMU measurements with Kalman Filter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信