胫骨前肌运动学胶带对脑卒中患者步态参数的影响

Emre Baskan, Muammer Çorum
{"title":"胫骨前肌运动学胶带对脑卒中患者步态参数的影响","authors":"Emre Baskan, Muammer Çorum","doi":"10.51972/tfsd.1024748","DOIUrl":null,"url":null,"abstract":": Purpose: The aim of this study is to examine the immediate effect of kinesiological taping on the tibialis anterior muscle with muscle stimulation technique on gait parameters in individuals with stroke. Material and Methods: The study included 28 stroke patients with a mean age of 53.57±12.38 years. Gait analysis was performed on the participants at different times with kinesiological taping and sham (plaster-rigid) taping and without any intervention. Kinesiological taping was applied to the tibialis anterior muscle using a muscle technique. Sham taping was applied along the tibialis anterior muscle from the origin to the insertion, with the ankle in a neutral position, without applying any tension to the muscle, skin or tape. The gait parameters of the participants were evaluated with the BTS G-Walk Analysis System. Results: According to the data obtained as a result of evaluations, it was concluded that the immediate effect of the kinesiological taping applied on the tibialis anterior muscle to the gait parameters was not statistically significant (p> 0.05). In addition, it was concluded that the kinesiological and sham taping applied to the tibialis anterior muscle is not superior to each other (p> 0.05). Conclusion: Kinesiological taping of the tibialis anterior muscle is not sufficient to improve gait functions in stroke patients.","PeriodicalId":239741,"journal":{"name":"Turkish Journal of Science and Health","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Kinesiological Taping Applied to the Tibialis Anterior Muscle on Gait Parameter in Stroke Patients\",\"authors\":\"Emre Baskan, Muammer Çorum\",\"doi\":\"10.51972/tfsd.1024748\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Purpose: The aim of this study is to examine the immediate effect of kinesiological taping on the tibialis anterior muscle with muscle stimulation technique on gait parameters in individuals with stroke. Material and Methods: The study included 28 stroke patients with a mean age of 53.57±12.38 years. Gait analysis was performed on the participants at different times with kinesiological taping and sham (plaster-rigid) taping and without any intervention. Kinesiological taping was applied to the tibialis anterior muscle using a muscle technique. Sham taping was applied along the tibialis anterior muscle from the origin to the insertion, with the ankle in a neutral position, without applying any tension to the muscle, skin or tape. The gait parameters of the participants were evaluated with the BTS G-Walk Analysis System. Results: According to the data obtained as a result of evaluations, it was concluded that the immediate effect of the kinesiological taping applied on the tibialis anterior muscle to the gait parameters was not statistically significant (p> 0.05). In addition, it was concluded that the kinesiological and sham taping applied to the tibialis anterior muscle is not superior to each other (p> 0.05). Conclusion: Kinesiological taping of the tibialis anterior muscle is not sufficient to improve gait functions in stroke patients.\",\"PeriodicalId\":239741,\"journal\":{\"name\":\"Turkish Journal of Science and Health\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Science and Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51972/tfsd.1024748\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Science and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51972/tfsd.1024748","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是探讨肌肉刺激技术对胫骨前肌进行运动学贴敷对脑卒中患者步态参数的直接影响。材料与方法:纳入脑卒中患者28例,平均年龄53.57±12.38岁。在没有任何干预的情况下,在不同时间对参与者进行运动学胶带和假(石膏-刚性)胶带的步态分析。使用肌肉技术将运动学胶带应用于胫骨前肌。假带沿胫骨前肌从起点至止点,踝关节处于中性位置,不给肌肉、皮肤或带施加任何张力。采用BTS G-Walk分析系统对参与者的步态参数进行评估。结果:根据评估得到的数据,认为胫骨前肌应用运动学胶带对步态参数的直接影响无统计学意义(p> 0.05)。此外,胫骨前肌的运动学和假捆扎效果无显著性差异(p> 0.05)。结论:胫骨前肌的运动学绑扎不足以改善脑卒中患者的步态功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Kinesiological Taping Applied to the Tibialis Anterior Muscle on Gait Parameter in Stroke Patients
: Purpose: The aim of this study is to examine the immediate effect of kinesiological taping on the tibialis anterior muscle with muscle stimulation technique on gait parameters in individuals with stroke. Material and Methods: The study included 28 stroke patients with a mean age of 53.57±12.38 years. Gait analysis was performed on the participants at different times with kinesiological taping and sham (plaster-rigid) taping and without any intervention. Kinesiological taping was applied to the tibialis anterior muscle using a muscle technique. Sham taping was applied along the tibialis anterior muscle from the origin to the insertion, with the ankle in a neutral position, without applying any tension to the muscle, skin or tape. The gait parameters of the participants were evaluated with the BTS G-Walk Analysis System. Results: According to the data obtained as a result of evaluations, it was concluded that the immediate effect of the kinesiological taping applied on the tibialis anterior muscle to the gait parameters was not statistically significant (p> 0.05). In addition, it was concluded that the kinesiological and sham taping applied to the tibialis anterior muscle is not superior to each other (p> 0.05). Conclusion: Kinesiological taping of the tibialis anterior muscle is not sufficient to improve gait functions in stroke patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信