{"title":"基于全相FFT1的三相功率相位测量","authors":"Z. Yonghui, Zhang Xiyuan, Chen Xi","doi":"10.1109/ICSPS.2010.5555703","DOIUrl":null,"url":null,"abstract":"When the Three-phase power signal containing multiple harmonics signal, there is a clear error that FFT algorithm is used directly to measure the phase, even with the various correction methods such as ratio method, center of energy gravity method etc. precision is severely constrained by harmonic signal. To solve these problems, a modified FFT algorithm, which is all-phase FFT, is used to measure the phase difference of three-phase power. The algorithm makes phase measurement accuracy significantly improve. More importantly, the way is almost free from harmonic noise, and easily implements in hardware to meet real-time measurement of power system requirements.","PeriodicalId":234084,"journal":{"name":"2010 2nd International Conference on Signal Processing Systems","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Phase measurement of three-phase power based on all-phase FFT1\",\"authors\":\"Z. Yonghui, Zhang Xiyuan, Chen Xi\",\"doi\":\"10.1109/ICSPS.2010.5555703\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When the Three-phase power signal containing multiple harmonics signal, there is a clear error that FFT algorithm is used directly to measure the phase, even with the various correction methods such as ratio method, center of energy gravity method etc. precision is severely constrained by harmonic signal. To solve these problems, a modified FFT algorithm, which is all-phase FFT, is used to measure the phase difference of three-phase power. The algorithm makes phase measurement accuracy significantly improve. More importantly, the way is almost free from harmonic noise, and easily implements in hardware to meet real-time measurement of power system requirements.\",\"PeriodicalId\":234084,\"journal\":{\"name\":\"2010 2nd International Conference on Signal Processing Systems\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 2nd International Conference on Signal Processing Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSPS.2010.5555703\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 2nd International Conference on Signal Processing Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPS.2010.5555703","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Phase measurement of three-phase power based on all-phase FFT1
When the Three-phase power signal containing multiple harmonics signal, there is a clear error that FFT algorithm is used directly to measure the phase, even with the various correction methods such as ratio method, center of energy gravity method etc. precision is severely constrained by harmonic signal. To solve these problems, a modified FFT algorithm, which is all-phase FFT, is used to measure the phase difference of three-phase power. The algorithm makes phase measurement accuracy significantly improve. More importantly, the way is almost free from harmonic noise, and easily implements in hardware to meet real-time measurement of power system requirements.