在微控制器上使用SMS监测Covid-19大流行期间的电能

M. F. Zambak
{"title":"在微控制器上使用SMS监测Covid-19大流行期间的电能","authors":"M. F. Zambak","doi":"10.30596/JCOSITTE.V1I2.4968","DOIUrl":null,"url":null,"abstract":"PT. PLN (Persero) has been getting prepaid and postpaid electricity program services, but in postpaid electricity programs, human errors often occur when officers read the kwh meter and PLN officials do not go down to residents' homes to record consumer usage due to the co-19 pandemic. In this research, an electrical energy monitoring tool was built using SMS (short massage service) based on the ATMEGA 2560 microcontroller that can measure and monitor the electrical energy consumption in real time using a voltage sensor and current sensor SCT013-030. The results of the current and voltage sensor readings will be forwarded to the ATMEGA 2560 microcontroller to be converted to the amount of electrical energy consumption and the amount of payment in accordance with the rates set by the PLN.","PeriodicalId":202535,"journal":{"name":"Journal of Computer Science, Information Technologi and Telecommunication Engineering","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Monitoring of Electrical Energy during the Covid-19 Pandemic Using SMS on Microcontrollers\",\"authors\":\"M. F. Zambak\",\"doi\":\"10.30596/JCOSITTE.V1I2.4968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PT. PLN (Persero) has been getting prepaid and postpaid electricity program services, but in postpaid electricity programs, human errors often occur when officers read the kwh meter and PLN officials do not go down to residents' homes to record consumer usage due to the co-19 pandemic. In this research, an electrical energy monitoring tool was built using SMS (short massage service) based on the ATMEGA 2560 microcontroller that can measure and monitor the electrical energy consumption in real time using a voltage sensor and current sensor SCT013-030. The results of the current and voltage sensor readings will be forwarded to the ATMEGA 2560 microcontroller to be converted to the amount of electrical energy consumption and the amount of payment in accordance with the rates set by the PLN.\",\"PeriodicalId\":202535,\"journal\":{\"name\":\"Journal of Computer Science, Information Technologi and Telecommunication Engineering\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Computer Science, Information Technologi and Telecommunication Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30596/JCOSITTE.V1I2.4968\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Science, Information Technologi and Telecommunication Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30596/JCOSITTE.V1I2.4968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

PT. PLN (Persero)一直在获得预付费和后付费的电力计划服务,但在后付费的电力计划中,由于covid -19大流行,工作人员在读取千瓦时电表时经常出现人为错误,PLN官员没有到居民家中记录消费者使用情况。在本研究中,基于ATMEGA 2560微控制器构建了一个基于SMS(短按摩服务)的电能监测工具,该工具可以使用电压传感器和电流传感器SCT013-030实时测量和监测电能消耗。电流和电压传感器读数的结果将被转发到ATMEGA 2560微控制器,根据PLN设定的费率转换为电能消耗和支付金额。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Monitoring of Electrical Energy during the Covid-19 Pandemic Using SMS on Microcontrollers
PT. PLN (Persero) has been getting prepaid and postpaid electricity program services, but in postpaid electricity programs, human errors often occur when officers read the kwh meter and PLN officials do not go down to residents' homes to record consumer usage due to the co-19 pandemic. In this research, an electrical energy monitoring tool was built using SMS (short massage service) based on the ATMEGA 2560 microcontroller that can measure and monitor the electrical energy consumption in real time using a voltage sensor and current sensor SCT013-030. The results of the current and voltage sensor readings will be forwarded to the ATMEGA 2560 microcontroller to be converted to the amount of electrical energy consumption and the amount of payment in accordance with the rates set by the PLN.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信