{"title":"谐波畸变下变压器模型的室内实验研究","authors":"R. Thompson, E. Makram, A. Girgis","doi":"10.1109/SSST.1988.17097","DOIUrl":null,"url":null,"abstract":"The authors investigate the variation of transformer parameters (self and mutual) with frequency by performing a laboratory experiment. The test measures a hybrid set of parameters on a single-phase and a three-phase transformer. This test investigates not only the variation of short-circuit parameters with frequency, but also the variation of open-circuit parameters with frequency. The authors extend the study to include the transformer load test. In this test, the load terminal voltages at different harmonic frequencies are measured.<<ETX>>","PeriodicalId":345412,"journal":{"name":"[1988] Proceedings. The Twentieth Southeastern Symposium on System Theory","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A laboratory experiment for transformer modeling in the presence of harmonic distortion\",\"authors\":\"R. Thompson, E. Makram, A. Girgis\",\"doi\":\"10.1109/SSST.1988.17097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors investigate the variation of transformer parameters (self and mutual) with frequency by performing a laboratory experiment. The test measures a hybrid set of parameters on a single-phase and a three-phase transformer. This test investigates not only the variation of short-circuit parameters with frequency, but also the variation of open-circuit parameters with frequency. The authors extend the study to include the transformer load test. In this test, the load terminal voltages at different harmonic frequencies are measured.<<ETX>>\",\"PeriodicalId\":345412,\"journal\":{\"name\":\"[1988] Proceedings. The Twentieth Southeastern Symposium on System Theory\",\"volume\":\"105 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1988] Proceedings. The Twentieth Southeastern Symposium on System Theory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSST.1988.17097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1988] Proceedings. The Twentieth Southeastern Symposium on System Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSST.1988.17097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A laboratory experiment for transformer modeling in the presence of harmonic distortion
The authors investigate the variation of transformer parameters (self and mutual) with frequency by performing a laboratory experiment. The test measures a hybrid set of parameters on a single-phase and a three-phase transformer. This test investigates not only the variation of short-circuit parameters with frequency, but also the variation of open-circuit parameters with frequency. The authors extend the study to include the transformer load test. In this test, the load terminal voltages at different harmonic frequencies are measured.<>