{"title":"涉及风能/太阳能/燃料电池发电厂的混合微电网试验台:设计和分析试验台","authors":"E. Kabalci, R. Bayindir, Eklas Hossain","doi":"10.1109/ICRERA.2014.7016511","DOIUrl":null,"url":null,"abstract":"This study introduces design, integration, control, and analysis of a hybrid microgrid (MG) testbed including a 300 kW wind energy plant of three 100-kW permanent magnet synchronous generators (PMSGs), 50 kW solar energy plant of 200 solar panels, and a 50 kW fuel cell stack. Generation side of the hybrid plant coupled on 120V dc bus where wind energy plant consists of uncontrolled diode rectifier and dc-dc buck converter rail while the solar and fuel cell plants are just controlled by dc-dc buck converters. The energy conversion of solar energy plant is operated by using proportional-integral (PI) controller assisted perturb and observe (P&O) maximum power point tracking (MPPT) algorithm. The dc-dc converters of the left generators are operated with PI controllers. All the dc-dc converters are constituted with mosfets that are switched at 30 kHz. The islanded AC grid of the plant is built by three-phase inverter that generates 480 V 60 Hz industrial voltages of the U.S. The inverter is operated by a sinusoidal pulse width (SPWM) modulator where the modulation index is set to 0.8 and switching frequency to 5 kHz. The proposed testbed is assumed essential to test and validate several case studies in terms of MG and renewable energy source integration issues. The most recent power control methods (PQ) and amplitude controls (V-f) can also be implemented by using the presented testbed.","PeriodicalId":243870,"journal":{"name":"2014 International Conference on Renewable Energy Research and Application (ICRERA)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":"{\"title\":\"Hybrid microgrid testbed involving wind/solar/fuel cell plants: A desing and analysis testbed\",\"authors\":\"E. Kabalci, R. Bayindir, Eklas Hossain\",\"doi\":\"10.1109/ICRERA.2014.7016511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study introduces design, integration, control, and analysis of a hybrid microgrid (MG) testbed including a 300 kW wind energy plant of three 100-kW permanent magnet synchronous generators (PMSGs), 50 kW solar energy plant of 200 solar panels, and a 50 kW fuel cell stack. Generation side of the hybrid plant coupled on 120V dc bus where wind energy plant consists of uncontrolled diode rectifier and dc-dc buck converter rail while the solar and fuel cell plants are just controlled by dc-dc buck converters. The energy conversion of solar energy plant is operated by using proportional-integral (PI) controller assisted perturb and observe (P&O) maximum power point tracking (MPPT) algorithm. The dc-dc converters of the left generators are operated with PI controllers. All the dc-dc converters are constituted with mosfets that are switched at 30 kHz. The islanded AC grid of the plant is built by three-phase inverter that generates 480 V 60 Hz industrial voltages of the U.S. The inverter is operated by a sinusoidal pulse width (SPWM) modulator where the modulation index is set to 0.8 and switching frequency to 5 kHz. The proposed testbed is assumed essential to test and validate several case studies in terms of MG and renewable energy source integration issues. The most recent power control methods (PQ) and amplitude controls (V-f) can also be implemented by using the presented testbed.\",\"PeriodicalId\":243870,\"journal\":{\"name\":\"2014 International Conference on Renewable Energy Research and Application (ICRERA)\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Renewable Energy Research and Application (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2014.7016511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Renewable Energy Research and Application (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2014.7016511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27
摘要
本研究介绍了一个混合微电网(MG)试验台的设计、集成、控制和分析,该试验台包括一个300千瓦的风力发电厂,三个100千瓦的永磁同步发电机(pmsg), 50千瓦的太阳能发电厂,200个太阳能电池板,和一个50千瓦的燃料电池堆。混合电厂的发电侧耦合在120V直流母线上,其中风能电厂由不可控二极管整流器和dc-dc降压变换器轨道组成,而太阳能和燃料电池电厂仅由dc-dc降压变换器控制。采用比例积分(PI)控制器辅助摄动与观测(P&O)最大功率点跟踪(MPPT)算法控制太阳能电站的能量转换。左侧发电机的dc-dc变换器由PI控制器操作。所有的dc-dc变换器都由在30khz切换的大多数场效应管组成。工厂的孤岛交流电网采用产生480 V 60 Hz美国工业电压的三相逆变器,逆变器采用正弦脉冲宽度(SPWM)调制器,调制指数为0.8,开关频率为5 kHz。该试验台被认为是测试和验证MG和可再生能源集成问题方面的几个案例研究的必要条件。最新的功率控制方法(PQ)和幅度控制(V-f)也可以通过使用该试验台来实现。
Hybrid microgrid testbed involving wind/solar/fuel cell plants: A desing and analysis testbed
This study introduces design, integration, control, and analysis of a hybrid microgrid (MG) testbed including a 300 kW wind energy plant of three 100-kW permanent magnet synchronous generators (PMSGs), 50 kW solar energy plant of 200 solar panels, and a 50 kW fuel cell stack. Generation side of the hybrid plant coupled on 120V dc bus where wind energy plant consists of uncontrolled diode rectifier and dc-dc buck converter rail while the solar and fuel cell plants are just controlled by dc-dc buck converters. The energy conversion of solar energy plant is operated by using proportional-integral (PI) controller assisted perturb and observe (P&O) maximum power point tracking (MPPT) algorithm. The dc-dc converters of the left generators are operated with PI controllers. All the dc-dc converters are constituted with mosfets that are switched at 30 kHz. The islanded AC grid of the plant is built by three-phase inverter that generates 480 V 60 Hz industrial voltages of the U.S. The inverter is operated by a sinusoidal pulse width (SPWM) modulator where the modulation index is set to 0.8 and switching frequency to 5 kHz. The proposed testbed is assumed essential to test and validate several case studies in terms of MG and renewable energy source integration issues. The most recent power control methods (PQ) and amplitude controls (V-f) can also be implemented by using the presented testbed.