{"title":"双轴跟踪vs固定PV:罗马尼亚一年试验期的能量响应","authors":"B. Burduhos, D. Diaconescu, S. Moraru, M. Badea, C. Grigorescu","doi":"10.1109/OPTIM.2012.6231971","DOIUrl":null,"url":null,"abstract":"The purpose of the current paper is to present and analyze the energetic results obtained from a stand-alone photovoltaic system, consisting of two differently orientated PV modules, over a period of one year of functioning. One of the modules is being pseudo-equatorially oriented along two axes based on an annual orientation program which will be described in the paper. The second PV module is installed on a fixed and optimally tilted frame orientated towards South. The paper also describes the electrical and the monitoring system used for measuring the parameters of the electrical energy produced. In the end of the paper a comparative analysis is made regarding the energetic response of the two tested photovoltaic systems in the geographical and meteorological conditions of the Braşov, Romania location during three most relevant day types (sunny, normal and cloudy days). Two main conclusions can be stated: firstly, non-deterministic orientation programs need to be developed, able to adapt themselves to the instantaneous ratio between direct and diffuse solar radiation; and secondly, the resistance of the consumer has the main role in transforming the whole incident solar radiation into electricity or only a part of it resulting in the need of using control systems capable of adapting the consumer resistance to the maximal power of the PV module.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"161 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Dual-axis tracked vs. fixed PV: Energetic response of one-year testing period in Romania\",\"authors\":\"B. Burduhos, D. Diaconescu, S. Moraru, M. Badea, C. Grigorescu\",\"doi\":\"10.1109/OPTIM.2012.6231971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of the current paper is to present and analyze the energetic results obtained from a stand-alone photovoltaic system, consisting of two differently orientated PV modules, over a period of one year of functioning. One of the modules is being pseudo-equatorially oriented along two axes based on an annual orientation program which will be described in the paper. The second PV module is installed on a fixed and optimally tilted frame orientated towards South. The paper also describes the electrical and the monitoring system used for measuring the parameters of the electrical energy produced. In the end of the paper a comparative analysis is made regarding the energetic response of the two tested photovoltaic systems in the geographical and meteorological conditions of the Braşov, Romania location during three most relevant day types (sunny, normal and cloudy days). Two main conclusions can be stated: firstly, non-deterministic orientation programs need to be developed, able to adapt themselves to the instantaneous ratio between direct and diffuse solar radiation; and secondly, the resistance of the consumer has the main role in transforming the whole incident solar radiation into electricity or only a part of it resulting in the need of using control systems capable of adapting the consumer resistance to the maximal power of the PV module.\",\"PeriodicalId\":382406,\"journal\":{\"name\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"volume\":\"161 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OPTIM.2012.6231971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文的目的是展示和分析由两个不同方向的光伏模块组成的独立光伏系统在一年的运行期间所获得的能量结果。其中一个模块是根据年度定向方案沿两个轴进行伪赤道定向,这将在本文中描述。第二个光伏组件安装在一个朝向南方的固定倾斜框架上。文中还介绍了用于测量所产生电能参数的电气和监控系统。最后,对比分析了两种测试光伏系统在罗马尼亚bra ov地区地理和气象条件下,在三种最相关的天气类型(晴天、正常天气和阴天)下的能量响应。可以得出两个主要结论:首先,需要开发非确定性定向程序,使其能够适应太阳直接辐射和漫射辐射之间的瞬时比;其次,消费者的电阻在将全部入射太阳辐射转化为电能或仅部分转化为电能方面起主要作用,因此需要使用能够使消费者电阻适应光伏组件最大功率的控制系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual-axis tracked vs. fixed PV: Energetic response of one-year testing period in Romania
The purpose of the current paper is to present and analyze the energetic results obtained from a stand-alone photovoltaic system, consisting of two differently orientated PV modules, over a period of one year of functioning. One of the modules is being pseudo-equatorially oriented along two axes based on an annual orientation program which will be described in the paper. The second PV module is installed on a fixed and optimally tilted frame orientated towards South. The paper also describes the electrical and the monitoring system used for measuring the parameters of the electrical energy produced. In the end of the paper a comparative analysis is made regarding the energetic response of the two tested photovoltaic systems in the geographical and meteorological conditions of the Braşov, Romania location during three most relevant day types (sunny, normal and cloudy days). Two main conclusions can be stated: firstly, non-deterministic orientation programs need to be developed, able to adapt themselves to the instantaneous ratio between direct and diffuse solar radiation; and secondly, the resistance of the consumer has the main role in transforming the whole incident solar radiation into electricity or only a part of it resulting in the need of using control systems capable of adapting the consumer resistance to the maximal power of the PV module.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信