酶免疫法测定皮质醇的多中心评价。

S Tunn, G Pappert, P Willnow, M Krieg
{"title":"酶免疫法测定皮质醇的多中心评价。","authors":"S Tunn,&nbsp;G Pappert,&nbsp;P Willnow,&nbsp;M Krieg","doi":"10.1515/cclm.1990.28.12.929","DOIUrl":null,"url":null,"abstract":"<p><p>The present paper describes a multicentre evaluation of a one step enzyme-immunoassay for the determination of cortisol in serum or plasma. Data from the investigation were analysed in terms of imprecision, detection limit, and correlation with other test methods. Within-run and between-run imprecisions (coefficient of variation) of Enzymun-Test Cortisol were less than 8% and 12%, respectively. The detection limit was 30 nmol/l (11 micrograms/l). With the exception of prednisolone, only low interference was found with other endogenous steroids. A good correlation between Enzymun-Test Cortisol and HPLC, LIA, FPIA and RIA was registered, although the latter two methods showed a scattering of regression lines from the different evaluators. The results show that Enzymun-Test Cortisol can be recommended as an alternative for the measurement of cortisol. As the method is calibrated against isotope dilution-mass spectrometry, results obtained with Enzymun-Test Cortisol are in agreement with the reference method.</p>","PeriodicalId":15649,"journal":{"name":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","volume":"28 12","pages":"929-35"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1990.28.12.929","citationCount":"24","resultStr":"{\"title\":\"Multicentre evaluation of an enzyme-immunoassay for cortisol determination.\",\"authors\":\"S Tunn,&nbsp;G Pappert,&nbsp;P Willnow,&nbsp;M Krieg\",\"doi\":\"10.1515/cclm.1990.28.12.929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present paper describes a multicentre evaluation of a one step enzyme-immunoassay for the determination of cortisol in serum or plasma. Data from the investigation were analysed in terms of imprecision, detection limit, and correlation with other test methods. Within-run and between-run imprecisions (coefficient of variation) of Enzymun-Test Cortisol were less than 8% and 12%, respectively. The detection limit was 30 nmol/l (11 micrograms/l). With the exception of prednisolone, only low interference was found with other endogenous steroids. A good correlation between Enzymun-Test Cortisol and HPLC, LIA, FPIA and RIA was registered, although the latter two methods showed a scattering of regression lines from the different evaluators. The results show that Enzymun-Test Cortisol can be recommended as an alternative for the measurement of cortisol. As the method is calibrated against isotope dilution-mass spectrometry, results obtained with Enzymun-Test Cortisol are in agreement with the reference method.</p>\",\"PeriodicalId\":15649,\"journal\":{\"name\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"volume\":\"28 12\",\"pages\":\"929-35\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1515/cclm.1990.28.12.929\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm.1990.28.12.929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1990.28.12.929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

本论文描述了一步酶免疫分析法测定血清或血浆皮质醇的多中心评价。对调查数据的不精确性、检出限以及与其他检测方法的相关性进行了分析。酶测皮质醇的运行内和运行间不精确度(变异系数)分别小于8%和12%。检出限为30 nmol/l(11微克/l)。除强的松龙外,其他内源性类固醇的干扰程度较低。酶测皮质醇与HPLC、LIA、FPIA和RIA之间具有良好的相关性,尽管后两种方法显示不同评估者的回归线分散。结果表明,酶测皮质醇可以推荐作为一种替代的测量皮质醇。由于该方法是根据同位素稀释质谱法校准的,酶测皮质醇得到的结果与参考方法一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multicentre evaluation of an enzyme-immunoassay for cortisol determination.

The present paper describes a multicentre evaluation of a one step enzyme-immunoassay for the determination of cortisol in serum or plasma. Data from the investigation were analysed in terms of imprecision, detection limit, and correlation with other test methods. Within-run and between-run imprecisions (coefficient of variation) of Enzymun-Test Cortisol were less than 8% and 12%, respectively. The detection limit was 30 nmol/l (11 micrograms/l). With the exception of prednisolone, only low interference was found with other endogenous steroids. A good correlation between Enzymun-Test Cortisol and HPLC, LIA, FPIA and RIA was registered, although the latter two methods showed a scattering of regression lines from the different evaluators. The results show that Enzymun-Test Cortisol can be recommended as an alternative for the measurement of cortisol. As the method is calibrated against isotope dilution-mass spectrometry, results obtained with Enzymun-Test Cortisol are in agreement with the reference method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信