中压PILC电缆PD-和tan(δ)-特性与温度和老化状态的关系

I. Mladenovic, C. Weindl
{"title":"中压PILC电缆PD-和tan(δ)-特性与温度和老化状态的关系","authors":"I. Mladenovic, C. Weindl","doi":"10.1109/EIC.2011.5996122","DOIUrl":null,"url":null,"abstract":"Diagnostic tools and methods for the state evaluation of MV (medium voltage) and HV (high voltage) power cables are mostly based on single key parameters like the partial discharge (PD) levels (inception voltage and intensity) or the values of the dissipation factor tan(δ). The main goals are the determination of the functionality and actual condition of the equipment. Additionally, the prediction of the rest life-time of power components could help to improve the investment planning and the maintenance strategy. In the field of cables and especially in case of PILC (Paper Insulated Lead Covered) cables, the requirements on the measurement technology and diagnostic systems are rather complex. In many cases the attention is directed to the methodology and the accuracy of the measurement equipment itself or to the value or spectrum of the measurement frequencies. However, the reliability of these methods is also very dependent on the experience of the test engineers and the knowledge and interpretation of all measured parameters. Therefore, besides the electrical parameters, in particular the temperature and humidity during the measurement, the equipment's dimensions, cable lengths and noise levels besides others must be taken into account. In this article, the principal dependencies of two major electrical criteria, which are the tan(δ)- and the PD-characteristics on the cable temperature and the cable age or the operational history of the cables, are presented. The strong correlation on e.g. the temperature makes clear, that the interpretation of a single criteria and a subsequent prognoses of the cable status are nearly impossible without further information. The derived results would be a subject of an immense scattering depending on seasonal influences, the load status during the disconnection of the analyzed lines, time constants, cable length, etc.","PeriodicalId":129127,"journal":{"name":"2011 Electrical Insulation Conference (EIC).","volume":"144 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Dependencies of the PD- and tan(δ)-characteristics on the temperature and ageing status of MV PILC cables\",\"authors\":\"I. Mladenovic, C. Weindl\",\"doi\":\"10.1109/EIC.2011.5996122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Diagnostic tools and methods for the state evaluation of MV (medium voltage) and HV (high voltage) power cables are mostly based on single key parameters like the partial discharge (PD) levels (inception voltage and intensity) or the values of the dissipation factor tan(δ). The main goals are the determination of the functionality and actual condition of the equipment. Additionally, the prediction of the rest life-time of power components could help to improve the investment planning and the maintenance strategy. In the field of cables and especially in case of PILC (Paper Insulated Lead Covered) cables, the requirements on the measurement technology and diagnostic systems are rather complex. In many cases the attention is directed to the methodology and the accuracy of the measurement equipment itself or to the value or spectrum of the measurement frequencies. However, the reliability of these methods is also very dependent on the experience of the test engineers and the knowledge and interpretation of all measured parameters. Therefore, besides the electrical parameters, in particular the temperature and humidity during the measurement, the equipment's dimensions, cable lengths and noise levels besides others must be taken into account. In this article, the principal dependencies of two major electrical criteria, which are the tan(δ)- and the PD-characteristics on the cable temperature and the cable age or the operational history of the cables, are presented. The strong correlation on e.g. the temperature makes clear, that the interpretation of a single criteria and a subsequent prognoses of the cable status are nearly impossible without further information. The derived results would be a subject of an immense scattering depending on seasonal influences, the load status during the disconnection of the analyzed lines, time constants, cable length, etc.\",\"PeriodicalId\":129127,\"journal\":{\"name\":\"2011 Electrical Insulation Conference (EIC).\",\"volume\":\"144 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Electrical Insulation Conference (EIC).\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.2011.5996122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Electrical Insulation Conference (EIC).","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2011.5996122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

中压(MV)和高压(HV)电力电缆状态评估的诊断工具和方法大多基于单个关键参数,如局部放电(PD)水平(起始电压和强度)或损耗因子tan(δ)的值。主要目标是确定设备的功能和实际状况。此外,对电力元件剩余寿命的预测有助于改进投资规划和维护策略。在电缆领域,特别是纸绝缘铅包电缆,对测量技术和诊断系统的要求相当复杂。在许多情况下,人们的注意力集中在测量设备本身的方法和准确性上,或者集中在测量频率的值或频谱上。然而,这些方法的可靠性也非常依赖于测试工程师的经验和所有测量参数的知识和解释。因此,除了电气参数,特别是测量过程中的温度和湿度外,还必须考虑设备的尺寸、电缆长度和噪声水平等。在本文中,介绍了两种主要电气标准,即tan(δ)-和pd -特性对电缆温度和电缆年龄或电缆运行历史的主要依赖关系。在温度等方面的强相关性清楚地表明,如果没有进一步的信息,对单一标准的解释和随后对电缆状态的预测几乎是不可能的。根据季节影响、分析线断开时的负载状态、时间常数、电缆长度等因素,导出的结果将是一个巨大的散射主题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dependencies of the PD- and tan(δ)-characteristics on the temperature and ageing status of MV PILC cables
Diagnostic tools and methods for the state evaluation of MV (medium voltage) and HV (high voltage) power cables are mostly based on single key parameters like the partial discharge (PD) levels (inception voltage and intensity) or the values of the dissipation factor tan(δ). The main goals are the determination of the functionality and actual condition of the equipment. Additionally, the prediction of the rest life-time of power components could help to improve the investment planning and the maintenance strategy. In the field of cables and especially in case of PILC (Paper Insulated Lead Covered) cables, the requirements on the measurement technology and diagnostic systems are rather complex. In many cases the attention is directed to the methodology and the accuracy of the measurement equipment itself or to the value or spectrum of the measurement frequencies. However, the reliability of these methods is also very dependent on the experience of the test engineers and the knowledge and interpretation of all measured parameters. Therefore, besides the electrical parameters, in particular the temperature and humidity during the measurement, the equipment's dimensions, cable lengths and noise levels besides others must be taken into account. In this article, the principal dependencies of two major electrical criteria, which are the tan(δ)- and the PD-characteristics on the cable temperature and the cable age or the operational history of the cables, are presented. The strong correlation on e.g. the temperature makes clear, that the interpretation of a single criteria and a subsequent prognoses of the cable status are nearly impossible without further information. The derived results would be a subject of an immense scattering depending on seasonal influences, the load status during the disconnection of the analyzed lines, time constants, cable length, etc.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信