动态抗干扰双电极心电采集系统的研制

C. M. Pereira, P. Mendes
{"title":"动态抗干扰双电极心电采集系统的研制","authors":"C. M. Pereira, P. Mendes","doi":"10.1109/ENBENG.2011.6026084","DOIUrl":null,"url":null,"abstract":"The aim of this work was the development of a two-electrode electrocardiogram acquisition system with dynamic interference rejection. The developed system is capable of measuring the electrocardiogram using only two electrodes due to its capacity to cancel the differential voltage from the 50 Hz interference signal. This capacity is given by a PLL circuit that generates a signal in phase opposition with the 50 Hz interference. The attenuation of the 50 Hz interference is not static due to the ability of canceling the interfering signal whatever its amplitude. This system proved to have a good performance in the elimination of the 50 Hz interference, particularly when the individual moves or gets closer to power sources with high levels of interference. The system is capable of measuring the electrocardiogram even when there is a small distance between electrodes.","PeriodicalId":206538,"journal":{"name":"1st Portuguese Biomedical Engineering Meeting","volume":"88 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Development of a two-electrode ECG acquisition system with dynamic interference rejection\",\"authors\":\"C. M. Pereira, P. Mendes\",\"doi\":\"10.1109/ENBENG.2011.6026084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this work was the development of a two-electrode electrocardiogram acquisition system with dynamic interference rejection. The developed system is capable of measuring the electrocardiogram using only two electrodes due to its capacity to cancel the differential voltage from the 50 Hz interference signal. This capacity is given by a PLL circuit that generates a signal in phase opposition with the 50 Hz interference. The attenuation of the 50 Hz interference is not static due to the ability of canceling the interfering signal whatever its amplitude. This system proved to have a good performance in the elimination of the 50 Hz interference, particularly when the individual moves or gets closer to power sources with high levels of interference. The system is capable of measuring the electrocardiogram even when there is a small distance between electrodes.\",\"PeriodicalId\":206538,\"journal\":{\"name\":\"1st Portuguese Biomedical Engineering Meeting\",\"volume\":\"88 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1st Portuguese Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ENBENG.2011.6026084\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1st Portuguese Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG.2011.6026084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

这项工作的目的是开发一种具有动态抗干扰功能的双电极心电图采集系统。开发的系统能够仅使用两个电极测量心电图,因为它能够消除来自50 Hz干扰信号的差分电压。这个容量是由一个锁相环电路给出的,它产生一个与50赫兹干扰相反的信号。50hz干扰的衰减不是静态的,因为无论其振幅如何,都可以抵消干扰信号。事实证明,该系统在消除50 Hz干扰方面具有良好的性能,特别是当个人移动或接近具有高干扰水平的电源时。该系统能够测量心电图,即使电极之间有很小的距离。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a two-electrode ECG acquisition system with dynamic interference rejection
The aim of this work was the development of a two-electrode electrocardiogram acquisition system with dynamic interference rejection. The developed system is capable of measuring the electrocardiogram using only two electrodes due to its capacity to cancel the differential voltage from the 50 Hz interference signal. This capacity is given by a PLL circuit that generates a signal in phase opposition with the 50 Hz interference. The attenuation of the 50 Hz interference is not static due to the ability of canceling the interfering signal whatever its amplitude. This system proved to have a good performance in the elimination of the 50 Hz interference, particularly when the individual moves or gets closer to power sources with high levels of interference. The system is capable of measuring the electrocardiogram even when there is a small distance between electrodes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信