{"title":"使用电凝法法,BOD含量下降和棕榈油废物鳕鱼下降","authors":"M. Masthura, Abdul Halim Daulay, Lansari Daulay","doi":"10.30829/jistech.v6i2.10014","DOIUrl":null,"url":null,"abstract":"Research using the electrocoagulation method has been carried out to determine the results of the sample test results for BOD and COD parameters in palm oil mill effluent. The electrodes used n this method are aluminium electrodes with varying adapter voltages of 6, 9, and 12 Volts. Palm oil liquid waste used comes from PTPN IV Adolina Perbaungan. The results of the study showed that before the electrocoagulation method the BOD value obtained was 243 mg/l, while after the electrocoagulation method the best results were obtained at a voltage of 12 Volt with a value of 52,5 mg/l. The value obtained before the electorocoagulation method was carried out on the COD parameter was 649 mg/l and after the electrocoagulation method the best results were obtained at a voltage of 12 Volt, which was 110 mg/l. This shows that the parameter values of BOD and COD in processed waste have decreased and meet the wastewater quality standards for the palm oil industry, namelyb 100 mg/l and 350 mg/l. The higher the value of the applied voltage, the more optimal the levels of BOD and COD.","PeriodicalId":142114,"journal":{"name":"JISTech (Journal of Islamic Science and Technology)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"PENURUNAN KANDUNGAN BOD DAN COD LIMBAH CAIR KELAPA SAWIT MENGGUNAKAN METODE ELEKTROKOAGULASI\",\"authors\":\"M. Masthura, Abdul Halim Daulay, Lansari Daulay\",\"doi\":\"10.30829/jistech.v6i2.10014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Research using the electrocoagulation method has been carried out to determine the results of the sample test results for BOD and COD parameters in palm oil mill effluent. The electrodes used n this method are aluminium electrodes with varying adapter voltages of 6, 9, and 12 Volts. Palm oil liquid waste used comes from PTPN IV Adolina Perbaungan. The results of the study showed that before the electrocoagulation method the BOD value obtained was 243 mg/l, while after the electrocoagulation method the best results were obtained at a voltage of 12 Volt with a value of 52,5 mg/l. The value obtained before the electorocoagulation method was carried out on the COD parameter was 649 mg/l and after the electrocoagulation method the best results were obtained at a voltage of 12 Volt, which was 110 mg/l. This shows that the parameter values of BOD and COD in processed waste have decreased and meet the wastewater quality standards for the palm oil industry, namelyb 100 mg/l and 350 mg/l. The higher the value of the applied voltage, the more optimal the levels of BOD and COD.\",\"PeriodicalId\":142114,\"journal\":{\"name\":\"JISTech (Journal of Islamic Science and Technology)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JISTech (Journal of Islamic Science and Technology)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30829/jistech.v6i2.10014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JISTech (Journal of Islamic Science and Technology)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30829/jistech.v6i2.10014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
采用电絮凝法对棕榈油厂出水的BOD和COD参数进行了样品测试结果的确定研究。这种方法中使用的电极是铝电极,适配器电压为6、9和12伏。使用的棕榈油废液来自PTPN IV Adolina Perbaungan。研究结果表明,电絮凝法前得到的BOD值为243 mg/l,电絮凝法后得到的BOD值在12伏电压下达到最佳,为52.5 mg/l。电絮凝法处理COD参数前的值为649 mg/l,电絮凝法处理后的最佳电压为12伏,为110 mg/l。由此可见,处理后的废水中BOD和COD的参数值有所下降,达到了棕榈油行业的废水水质标准,即100 mg/l和350 mg/l。施加电压值越高,BOD和COD水平越理想。
PENURUNAN KANDUNGAN BOD DAN COD LIMBAH CAIR KELAPA SAWIT MENGGUNAKAN METODE ELEKTROKOAGULASI
Research using the electrocoagulation method has been carried out to determine the results of the sample test results for BOD and COD parameters in palm oil mill effluent. The electrodes used n this method are aluminium electrodes with varying adapter voltages of 6, 9, and 12 Volts. Palm oil liquid waste used comes from PTPN IV Adolina Perbaungan. The results of the study showed that before the electrocoagulation method the BOD value obtained was 243 mg/l, while after the electrocoagulation method the best results were obtained at a voltage of 12 Volt with a value of 52,5 mg/l. The value obtained before the electorocoagulation method was carried out on the COD parameter was 649 mg/l and after the electrocoagulation method the best results were obtained at a voltage of 12 Volt, which was 110 mg/l. This shows that the parameter values of BOD and COD in processed waste have decreased and meet the wastewater quality standards for the palm oil industry, namelyb 100 mg/l and 350 mg/l. The higher the value of the applied voltage, the more optimal the levels of BOD and COD.