接地规范的模糊性:重新审视IEC 62305

S. C. Lim, Chandima Gomes, M. A. Kadir, J. Jasni
{"title":"接地规范的模糊性:重新审视IEC 62305","authors":"S. C. Lim, Chandima Gomes, M. A. Kadir, J. Jasni","doi":"10.1109/ICLP.2012.6344293","DOIUrl":null,"url":null,"abstract":"Grounding issues related to lightning currents have been addressed giving special attention to recommended practices in IEC 62305 (2010). Unambiguous recommendations are needed for the requirement of type A system or type B system or both systems for a given installation. Specifications of the length of conductors, based on the level of protection, were critically analyzed emphasizing the human risk related issues. Calculations reveal that at Level III and IV, the specified lengths of type A conductors may give step potentials, especially in highly resistive soils that may drive currents through human beings in the vicinity, exceeding lethal energy. Furthermore, specification of the limiting value of resistance for transient grounding systems may lead to hazardous situations as the difference between frequency dependent impedance and low frequency resistance may increase to very high values at Mega Hertz range where lightning energy spectrum has significant amplitude. Covering of a sizable surface area surrounding the grounding conductors with insulation material, is recommended as a practical solution to this issue.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Ambiguity of grounding specifications: IEC 62305 revisited\",\"authors\":\"S. C. Lim, Chandima Gomes, M. A. Kadir, J. Jasni\",\"doi\":\"10.1109/ICLP.2012.6344293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Grounding issues related to lightning currents have been addressed giving special attention to recommended practices in IEC 62305 (2010). Unambiguous recommendations are needed for the requirement of type A system or type B system or both systems for a given installation. Specifications of the length of conductors, based on the level of protection, were critically analyzed emphasizing the human risk related issues. Calculations reveal that at Level III and IV, the specified lengths of type A conductors may give step potentials, especially in highly resistive soils that may drive currents through human beings in the vicinity, exceeding lethal energy. Furthermore, specification of the limiting value of resistance for transient grounding systems may lead to hazardous situations as the difference between frequency dependent impedance and low frequency resistance may increase to very high values at Mega Hertz range where lightning energy spectrum has significant amplitude. Covering of a sizable surface area surrounding the grounding conductors with insulation material, is recommended as a practical solution to this issue.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

与雷电电流有关的接地问题已得到解决,并特别注意IEC 62305(2010)中的推荐做法。对于给定安装的A型系统或B型系统或两种系统的要求,需要明确的建议。根据保护级别,严格分析了导体长度的规格,强调了与人类风险相关的问题。计算表明,在III级和IV级,A型导体的规定长度可能会产生超过致死能量的阶跃电位,特别是在高电阻土壤中,可能会驱动电流通过附近的人类。此外,瞬态接地系统的阻值限值的规定可能会导致危险情况,因为频率相关阻抗和低频电阻之间的差值可能会在兆赫范围内增加到非常高的值,而闪电能谱具有显著的幅度。建议在接地导体周围覆盖一定面积的绝缘材料,这是一种实用的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ambiguity of grounding specifications: IEC 62305 revisited
Grounding issues related to lightning currents have been addressed giving special attention to recommended practices in IEC 62305 (2010). Unambiguous recommendations are needed for the requirement of type A system or type B system or both systems for a given installation. Specifications of the length of conductors, based on the level of protection, were critically analyzed emphasizing the human risk related issues. Calculations reveal that at Level III and IV, the specified lengths of type A conductors may give step potentials, especially in highly resistive soils that may drive currents through human beings in the vicinity, exceeding lethal energy. Furthermore, specification of the limiting value of resistance for transient grounding systems may lead to hazardous situations as the difference between frequency dependent impedance and low frequency resistance may increase to very high values at Mega Hertz range where lightning energy spectrum has significant amplitude. Covering of a sizable surface area surrounding the grounding conductors with insulation material, is recommended as a practical solution to this issue.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信