{"title":"带水平集热器的热泵功率分析","authors":"A. Craciun, F. Sandu, G. Pana","doi":"10.1109/OPTIM.2012.6231924","DOIUrl":null,"url":null,"abstract":"This paper presents some practical considerations for a residential heat pump system: the implementation of the ground loop, the power consumption during the 2010-2011 heating season, a comparison between a heat pump and a gas furnace heating system from the power point of view, the temperature monitoring subsystem and the ground temperature variations for one year period. The main goal of the paper is to demonstrate the heat pump advantages.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power analysis of a heat pump with horizontal collectors\",\"authors\":\"A. Craciun, F. Sandu, G. Pana\",\"doi\":\"10.1109/OPTIM.2012.6231924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents some practical considerations for a residential heat pump system: the implementation of the ground loop, the power consumption during the 2010-2011 heating season, a comparison between a heat pump and a gas furnace heating system from the power point of view, the temperature monitoring subsystem and the ground temperature variations for one year period. The main goal of the paper is to demonstrate the heat pump advantages.\",\"PeriodicalId\":382406,\"journal\":{\"name\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OPTIM.2012.6231924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power analysis of a heat pump with horizontal collectors
This paper presents some practical considerations for a residential heat pump system: the implementation of the ground loop, the power consumption during the 2010-2011 heating season, a comparison between a heat pump and a gas furnace heating system from the power point of view, the temperature monitoring subsystem and the ground temperature variations for one year period. The main goal of the paper is to demonstrate the heat pump advantages.