S. Digă, I. Pătru, Nicolae Digă, I. Mircea, P. Mircea
{"title":"与室内照明装置有关的光度计算和参数监测方面","authors":"S. Digă, I. Pătru, Nicolae Digă, I. Mircea, P. Mircea","doi":"10.1109/Lighting56379.2022.9929029","DOIUrl":null,"url":null,"abstract":"In this paper, the authors present a systematized and clear methodology for calculation and monitoring using specialized equipment of direct illuminances produced by linear light sources. A room with the destination of an academic didactic laboratory was chosen as a case study. The electric lighting of the room is achieved by means of two types of luminaires equipped with tubular fluorescent lamps with a power of 18 W and 36 W respectively.","PeriodicalId":198420,"journal":{"name":"2022 Seventh Junior Conference on Lighting (Lighting)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aspects of Photometric Calculation and Monitoring of Parameters Related to an Interior Lighting Installation\",\"authors\":\"S. Digă, I. Pătru, Nicolae Digă, I. Mircea, P. Mircea\",\"doi\":\"10.1109/Lighting56379.2022.9929029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the authors present a systematized and clear methodology for calculation and monitoring using specialized equipment of direct illuminances produced by linear light sources. A room with the destination of an academic didactic laboratory was chosen as a case study. The electric lighting of the room is achieved by means of two types of luminaires equipped with tubular fluorescent lamps with a power of 18 W and 36 W respectively.\",\"PeriodicalId\":198420,\"journal\":{\"name\":\"2022 Seventh Junior Conference on Lighting (Lighting)\",\"volume\":\"105 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Seventh Junior Conference on Lighting (Lighting)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/Lighting56379.2022.9929029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Seventh Junior Conference on Lighting (Lighting)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/Lighting56379.2022.9929029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Aspects of Photometric Calculation and Monitoring of Parameters Related to an Interior Lighting Installation
In this paper, the authors present a systematized and clear methodology for calculation and monitoring using specialized equipment of direct illuminances produced by linear light sources. A room with the destination of an academic didactic laboratory was chosen as a case study. The electric lighting of the room is achieved by means of two types of luminaires equipped with tubular fluorescent lamps with a power of 18 W and 36 W respectively.