测量不确定度模型在含频率搅拌混响室中的适用性

A. Gifuni, M. Migliaccio, L. Bastianelli, F. Moglie, V. M. Primiani, G. Gradoni
{"title":"测量不确定度模型在含频率搅拌混响室中的适用性","authors":"A. Gifuni, M. Migliaccio, L. Bastianelli, F. Moglie, V. M. Primiani, G. Gradoni","doi":"10.1109/EMCSI.2018.8495183","DOIUrl":null,"url":null,"abstract":"We analyze the uncertainty of measurements carried out in a reverberation chamber. The adopted model includes the frequency stirring method and different $K$ -Factor values. Two majorants are proposed to enhance the uncertainty computation of the chamber insertion loss.","PeriodicalId":120342,"journal":{"name":"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Applicability of Measurement Uncertainty Models in a Reverberation Chamber Including Frequency Stirring\",\"authors\":\"A. Gifuni, M. Migliaccio, L. Bastianelli, F. Moglie, V. M. Primiani, G. Gradoni\",\"doi\":\"10.1109/EMCSI.2018.8495183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We analyze the uncertainty of measurements carried out in a reverberation chamber. The adopted model includes the frequency stirring method and different $K$ -Factor values. Two majorants are proposed to enhance the uncertainty computation of the chamber insertion loss.\",\"PeriodicalId\":120342,\"journal\":{\"name\":\"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCSI.2018.8495183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCSI.2018.8495183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

我们分析了在混响室内进行的测量的不确定度。所采用的模型包括频率搅拌方法和不同的K因子值。提出了两种主要方法来增强腔室插入损失的不确定性计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Applicability of Measurement Uncertainty Models in a Reverberation Chamber Including Frequency Stirring
We analyze the uncertainty of measurements carried out in a reverberation chamber. The adopted model includes the frequency stirring method and different $K$ -Factor values. Two majorants are proposed to enhance the uncertainty computation of the chamber insertion loss.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信