环境修复用锗条探测器的研制

B. Phlips, W. N. Johnson, R. Kroeger, J. Kurfess, G. Phillips, E. Wulf, P. Luke
{"title":"环境修复用锗条探测器的研制","authors":"B. Phlips, W. N. Johnson, R. Kroeger, J. Kurfess, G. Phillips, E. Wulf, P. Luke","doi":"10.1109/NSSMIC.2000.949051","DOIUrl":null,"url":null,"abstract":"We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array consists of four detectors, 5/spl times/5/spl times/1 cm each with 25 strips on each side. The detectors are daisy-chained to hybrid preamplifiers to reduce the number of channels of electronics. Good spectroscopy and imaging are achieved. We also present results from the development of an amorphous germanium contact technology as an alternative to the lithium contact technology. A prototype 25 by 25 strip detector was manufactured with this new technology and demonstrates good spectroscopy and imaging.","PeriodicalId":445100,"journal":{"name":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Development of germanium strip detectors for environmental remediation\",\"authors\":\"B. Phlips, W. N. Johnson, R. Kroeger, J. Kurfess, G. Phillips, E. Wulf, P. Luke\",\"doi\":\"10.1109/NSSMIC.2000.949051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array consists of four detectors, 5/spl times/5/spl times/1 cm each with 25 strips on each side. The detectors are daisy-chained to hybrid preamplifiers to reduce the number of channels of electronics. Good spectroscopy and imaging are achieved. We also present results from the development of an amorphous germanium contact technology as an alternative to the lithium contact technology. A prototype 25 by 25 strip detector was manufactured with this new technology and demonstrates good spectroscopy and imaging.\",\"PeriodicalId\":445100,\"journal\":{\"name\":\"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2000.949051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2000.949051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

我们提出了用于伽马射线源成像和高分辨率光谱的第一个锗条探测器阵列的初步结果。该阵列由四个探测器组成,每个探测器5/spl倍/5/spl倍/1厘米,每侧25条。检测器被连接到混合前置放大器上,以减少电子通道的数量。实现了良好的光谱学和成像。我们还介绍了一种非晶锗触点技术的发展结果,作为锂触点技术的替代品。用这种新技术制造了一个25 × 25条探测器的原型,并证明了良好的光谱和成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of germanium strip detectors for environmental remediation
We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array consists of four detectors, 5/spl times/5/spl times/1 cm each with 25 strips on each side. The detectors are daisy-chained to hybrid preamplifiers to reduce the number of channels of electronics. Good spectroscopy and imaging are achieved. We also present results from the development of an amorphous germanium contact technology as an alternative to the lithium contact technology. A prototype 25 by 25 strip detector was manufactured with this new technology and demonstrates good spectroscopy and imaging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信