基于质量因子匹配技术的19.6 dB输入功率范围403mhz整流器

NgocDuc Au, C. Seo, K. Park, Seungmo Hong
{"title":"基于质量因子匹配技术的19.6 dB输入功率范围403mhz整流器","authors":"NgocDuc Au, C. Seo, K. Park, Seungmo Hong","doi":"10.1109/WPTC45513.2019.9055538","DOIUrl":null,"url":null,"abstract":"To extend the input power range and increase RF sensitivity for energy harvesting in medical implant communication service (MICS) band, a high quality (Q) matching network is applied in 403 MHz rectifier circuit. In this proposed design, a finite unload Q series inductor is placed between a pair of shunt capacitors to enhance the overall load Q factor of impedance matching network when compared with conventional type. By using lump components, the compact size of rectifier is 1.4 cm x 0.8 cm that suitable for medical implant devices in human body tissue. The compact-size rectifier has the measured efficiency $(\\eta)$ where the input power range for $\\eta$ above 50.1 % is from -8.1 dBm (RF sensitivity) to 11.5 dBm and thus, the input power range of 19.6 dB is achieved. At 5 dBm the peak efficiency is 68.1 %.","PeriodicalId":148719,"journal":{"name":"2019 IEEE Wireless Power Transfer Conference (WPTC)","volume":"36 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 19.6 dB Input Power Range 403 MHz Rectifier Based on Quality Factor in Matching Technique\",\"authors\":\"NgocDuc Au, C. Seo, K. Park, Seungmo Hong\",\"doi\":\"10.1109/WPTC45513.2019.9055538\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To extend the input power range and increase RF sensitivity for energy harvesting in medical implant communication service (MICS) band, a high quality (Q) matching network is applied in 403 MHz rectifier circuit. In this proposed design, a finite unload Q series inductor is placed between a pair of shunt capacitors to enhance the overall load Q factor of impedance matching network when compared with conventional type. By using lump components, the compact size of rectifier is 1.4 cm x 0.8 cm that suitable for medical implant devices in human body tissue. The compact-size rectifier has the measured efficiency $(\\\\eta)$ where the input power range for $\\\\eta$ above 50.1 % is from -8.1 dBm (RF sensitivity) to 11.5 dBm and thus, the input power range of 19.6 dB is achieved. At 5 dBm the peak efficiency is 68.1 %.\",\"PeriodicalId\":148719,\"journal\":{\"name\":\"2019 IEEE Wireless Power Transfer Conference (WPTC)\",\"volume\":\"36 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Wireless Power Transfer Conference (WPTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WPTC45513.2019.9055538\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Wireless Power Transfer Conference (WPTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WPTC45513.2019.9055538","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了扩大医疗植入通信服务(MICS)频段能量采集的输入功率范围和提高射频灵敏度,在403mhz整流电路中采用了高质量匹配网络。在此设计中,在一对并联电容之间放置一个有限卸载Q系列电感器,以提高阻抗匹配网络的整体负载Q因子。采用块状元件,整流器的紧凑尺寸为1.4 cm x 0.8 cm,适合于人体组织中的医疗植入装置。紧凑尺寸的整流器具有测量效率$(\eta)$,其中$\eta$高于50.1%的输入功率范围从-8.1 dBm (RF灵敏度)到11.5 dBm,因此,输入功率范围为19.6 dB。在5 dBm时,峰值效率为68.1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A 19.6 dB Input Power Range 403 MHz Rectifier Based on Quality Factor in Matching Technique
To extend the input power range and increase RF sensitivity for energy harvesting in medical implant communication service (MICS) band, a high quality (Q) matching network is applied in 403 MHz rectifier circuit. In this proposed design, a finite unload Q series inductor is placed between a pair of shunt capacitors to enhance the overall load Q factor of impedance matching network when compared with conventional type. By using lump components, the compact size of rectifier is 1.4 cm x 0.8 cm that suitable for medical implant devices in human body tissue. The compact-size rectifier has the measured efficiency $(\eta)$ where the input power range for $\eta$ above 50.1 % is from -8.1 dBm (RF sensitivity) to 11.5 dBm and thus, the input power range of 19.6 dB is achieved. At 5 dBm the peak efficiency is 68.1 %.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信