差分相位检测在表面等离子体共振传感器灵敏度提高中的应用

H. Ho, S.Y. Wu, W. Law, Chinlon Lin
{"title":"差分相位检测在表面等离子体共振传感器灵敏度提高中的应用","authors":"H. Ho, S.Y. Wu, W. Law, Chinlon Lin","doi":"10.1109/APBP.2004.1412361","DOIUrl":null,"url":null,"abstract":"Surface plasmon resonance (SPR) is an effective tool for quantitative detection of binding reaction between biomolecules. Currently SPR sensors are mainly based on measuring the angular shift associated with biomolecular adhesion. In fact it has been shown that the phase jump across the SPR dip is very steep, and consequently better sensitivity may be achieved by measuring the optical phase. In this presentation, we report interferometric techniques we have developed in our laboratory for achieving SPR phase detection. We also demonstrate that the incorporation of differential phase detection can further improve the performance of SPR biosensors. Currently the experimental sensitivity of our differential phase setup is 5.48/spl times/10/sup -8/ refractive index unit (RIU), which is three times better than that reported from conventional angular systems.","PeriodicalId":346624,"journal":{"name":"The Second Asian and Pacific Rim Symposium on Biophotonics, 2004. APBP 2004.","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of differential phase detection for sensitivity improvement in surface plasmon resonance sensors\",\"authors\":\"H. Ho, S.Y. Wu, W. Law, Chinlon Lin\",\"doi\":\"10.1109/APBP.2004.1412361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Surface plasmon resonance (SPR) is an effective tool for quantitative detection of binding reaction between biomolecules. Currently SPR sensors are mainly based on measuring the angular shift associated with biomolecular adhesion. In fact it has been shown that the phase jump across the SPR dip is very steep, and consequently better sensitivity may be achieved by measuring the optical phase. In this presentation, we report interferometric techniques we have developed in our laboratory for achieving SPR phase detection. We also demonstrate that the incorporation of differential phase detection can further improve the performance of SPR biosensors. Currently the experimental sensitivity of our differential phase setup is 5.48/spl times/10/sup -8/ refractive index unit (RIU), which is three times better than that reported from conventional angular systems.\",\"PeriodicalId\":346624,\"journal\":{\"name\":\"The Second Asian and Pacific Rim Symposium on Biophotonics, 2004. APBP 2004.\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Second Asian and Pacific Rim Symposium on Biophotonics, 2004. APBP 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APBP.2004.1412361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Second Asian and Pacific Rim Symposium on Biophotonics, 2004. APBP 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APBP.2004.1412361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

表面等离子体共振(SPR)是定量检测生物分子间结合反应的有效工具。目前SPR传感器主要是基于测量与生物分子粘附相关的角位移。事实上,已经证明,在SPR倾角上的相位跳跃非常陡峭,因此通过测量光学相位可以获得更好的灵敏度。在本报告中,我们报告了我们在实验室开发的用于实现SPR相位检测的干涉测量技术。我们还证明了差分相位检测的结合可以进一步提高SPR生物传感器的性能。目前,我们的差分相位装置的实验灵敏度为5.48/spl倍/10/sup -8/折射率单位(RIU),是传统角度系统的3倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of differential phase detection for sensitivity improvement in surface plasmon resonance sensors
Surface plasmon resonance (SPR) is an effective tool for quantitative detection of binding reaction between biomolecules. Currently SPR sensors are mainly based on measuring the angular shift associated with biomolecular adhesion. In fact it has been shown that the phase jump across the SPR dip is very steep, and consequently better sensitivity may be achieved by measuring the optical phase. In this presentation, we report interferometric techniques we have developed in our laboratory for achieving SPR phase detection. We also demonstrate that the incorporation of differential phase detection can further improve the performance of SPR biosensors. Currently the experimental sensitivity of our differential phase setup is 5.48/spl times/10/sup -8/ refractive index unit (RIU), which is three times better than that reported from conventional angular systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信