{"title":"SF/sub - 6/绝缘GIS三相共机箱内击穿的数值模拟与实验测量","authors":"Xu Jianyuan, W. Haifeng, Zhao Jisheng, Shi Fengyi","doi":"10.1109/ICEMS.2001.970764","DOIUrl":null,"url":null,"abstract":"The three-dimensional electric field inside a 3-phase common enclosure SF/sub 6/ GIS was calculated by the finite element method. From the calculating results the electric field distribution on the surface of the porcelain pole type insulator and disc type insulator were derived. To be associated with the calculating results an experimental research was taken and the breakdown voltage was measured.","PeriodicalId":143007,"journal":{"name":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The numerical simulation and experimental measurement of electric breakdown inside the three-phase common enclosure SF/sub 6/ insulated GIS\",\"authors\":\"Xu Jianyuan, W. Haifeng, Zhao Jisheng, Shi Fengyi\",\"doi\":\"10.1109/ICEMS.2001.970764\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The three-dimensional electric field inside a 3-phase common enclosure SF/sub 6/ GIS was calculated by the finite element method. From the calculating results the electric field distribution on the surface of the porcelain pole type insulator and disc type insulator were derived. To be associated with the calculating results an experimental research was taken and the breakdown voltage was measured.\",\"PeriodicalId\":143007,\"journal\":{\"name\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMS.2001.970764\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2001.970764","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The numerical simulation and experimental measurement of electric breakdown inside the three-phase common enclosure SF/sub 6/ insulated GIS
The three-dimensional electric field inside a 3-phase common enclosure SF/sub 6/ GIS was calculated by the finite element method. From the calculating results the electric field distribution on the surface of the porcelain pole type insulator and disc type insulator were derived. To be associated with the calculating results an experimental research was taken and the breakdown voltage was measured.