基于壳聚糖薄膜光学荧光传感器的二硝基苯线性和非线性传感

A. M. Yusufu, A. S. M. Noor, H. Azami, N. Tamchek, Z. Abidin
{"title":"基于壳聚糖薄膜光学荧光传感器的二硝基苯线性和非线性传感","authors":"A. M. Yusufu, A. S. M. Noor, H. Azami, N. Tamchek, Z. Abidin","doi":"10.1109/ICSENST.2015.7438474","DOIUrl":null,"url":null,"abstract":"We presented here the findings of linear and nonlinear excitation of an optical fluorescence sensor enhanced with chitosan-based thin films coated on tapered optical fiber for detecting of dinitrobenzene solution compound. The absorbance peak of linear excitation at 441.2 nm shows a small shift to from 540.8 nm to 541.3 nm when 0.003g/ml dinitrobenzene was diluted in acetone. Time resolved fluorescence resulting in decreasing of fluorescence intensities was recorded for both linear and nonlinear excitation. Both showed an agreement of quenching of fluorescence up to 30% of its initial fluorescence due to the free electron transfer from chitosan thin film to the dinitrobenzene. Nonlinear excitation gives more rapid time-resolved florescence after 4 minutes compared to 6 minutes in linear excitation.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dinitrobenzene sensing utilizing chitosan-based thin films optical fluorescence sensors via linear and nonlinear excitation\",\"authors\":\"A. M. Yusufu, A. S. M. Noor, H. Azami, N. Tamchek, Z. Abidin\",\"doi\":\"10.1109/ICSENST.2015.7438474\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We presented here the findings of linear and nonlinear excitation of an optical fluorescence sensor enhanced with chitosan-based thin films coated on tapered optical fiber for detecting of dinitrobenzene solution compound. The absorbance peak of linear excitation at 441.2 nm shows a small shift to from 540.8 nm to 541.3 nm when 0.003g/ml dinitrobenzene was diluted in acetone. Time resolved fluorescence resulting in decreasing of fluorescence intensities was recorded for both linear and nonlinear excitation. Both showed an agreement of quenching of fluorescence up to 30% of its initial fluorescence due to the free electron transfer from chitosan thin film to the dinitrobenzene. Nonlinear excitation gives more rapid time-resolved florescence after 4 minutes compared to 6 minutes in linear excitation.\",\"PeriodicalId\":375376,\"journal\":{\"name\":\"2015 9th International Conference on Sensing Technology (ICST)\",\"volume\":\"134 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 9th International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2015.7438474\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2015.7438474","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文报道了在锥形光纤表面涂覆壳聚糖基薄膜增强光学荧光传感器用于检测二硝基苯溶液化合物的线性和非线性激发的研究结果。当0.003g/ml二硝基苯在丙酮中稀释时,在441.2 nm处的线激发吸光度峰从540.8 nm小幅移动到541.3 nm。在线性和非线性激发下均记录到时间分辨荧光,导致荧光强度降低。由于自由电子从壳聚糖薄膜转移到二硝基苯上,两者都显示出高达30%的初始荧光猝灭的一致性。与线性激发6分钟相比,非线性激发在4分钟后产生更快的时间分辨荧光。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dinitrobenzene sensing utilizing chitosan-based thin films optical fluorescence sensors via linear and nonlinear excitation
We presented here the findings of linear and nonlinear excitation of an optical fluorescence sensor enhanced with chitosan-based thin films coated on tapered optical fiber for detecting of dinitrobenzene solution compound. The absorbance peak of linear excitation at 441.2 nm shows a small shift to from 540.8 nm to 541.3 nm when 0.003g/ml dinitrobenzene was diluted in acetone. Time resolved fluorescence resulting in decreasing of fluorescence intensities was recorded for both linear and nonlinear excitation. Both showed an agreement of quenching of fluorescence up to 30% of its initial fluorescence due to the free electron transfer from chitosan thin film to the dinitrobenzene. Nonlinear excitation gives more rapid time-resolved florescence after 4 minutes compared to 6 minutes in linear excitation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信