6.6 kv配电绝缘子表面V-t特性近似公式

Satoshi Matsumoto, Tomoyuki Sato, Hideki Honda, Shigeru Yokoyama
{"title":"6.6 kv配电绝缘子表面V-t特性近似公式","authors":"Satoshi Matsumoto, Tomoyuki Sato, Hideki Honda, Shigeru Yokoyama","doi":"10.1109/ICLP.2012.6344282","DOIUrl":null,"url":null,"abstract":"Many factors are required to be considered when determining efficient lightning protection methods for power distribution lines, including the causes of lightning surge and the topology and insulation level of the power distribution lines. This study experimentally clarifies the flashover characteristics of 6.6-kV power distribution insulators currently being used by considering polarity differences and polluted conditions. Furthermore, this study proposes an approximate formula that is based on the sparkover model to calculate the flashover characteristics of 6.6-kV power distribution insulators, and contributes to the improvement in insulation coordination throughout power distribution systems.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Approximate formula for surface V-t characteristics of 6.6-kV distribution insulator\",\"authors\":\"Satoshi Matsumoto, Tomoyuki Sato, Hideki Honda, Shigeru Yokoyama\",\"doi\":\"10.1109/ICLP.2012.6344282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many factors are required to be considered when determining efficient lightning protection methods for power distribution lines, including the causes of lightning surge and the topology and insulation level of the power distribution lines. This study experimentally clarifies the flashover characteristics of 6.6-kV power distribution insulators currently being used by considering polarity differences and polluted conditions. Furthermore, this study proposes an approximate formula that is based on the sparkover model to calculate the flashover characteristics of 6.6-kV power distribution insulators, and contributes to the improvement in insulation coordination throughout power distribution systems.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344282\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在确定有效的配电线路防雷方法时,需要考虑很多因素,包括雷涌产生的原因、配电线路的拓扑结构和绝缘等级等。本研究通过实验明确了目前使用的6.6 kv配电绝缘子在考虑极性差异和污染条件下的闪络特性。此外,本文还提出了基于闪络模型的6.6 kv配电绝缘子闪络特性近似计算公式,有助于提高整个配电系统的绝缘协调性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Approximate formula for surface V-t characteristics of 6.6-kV distribution insulator
Many factors are required to be considered when determining efficient lightning protection methods for power distribution lines, including the causes of lightning surge and the topology and insulation level of the power distribution lines. This study experimentally clarifies the flashover characteristics of 6.6-kV power distribution insulators currently being used by considering polarity differences and polluted conditions. Furthermore, this study proposes an approximate formula that is based on the sparkover model to calculate the flashover characteristics of 6.6-kV power distribution insulators, and contributes to the improvement in insulation coordination throughout power distribution systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信