l型皮托管校准时最佳安装位置的研究

Xingen Liu, Xia Li, Lingshan Yang, Weihui Zhou, Yang Xiang
{"title":"l型皮托管校准时最佳安装位置的研究","authors":"Xingen Liu, Xia Li, Lingshan Yang, Weihui Zhou, Yang Xiang","doi":"10.1109/ICEMI52946.2021.9679525","DOIUrl":null,"url":null,"abstract":"In this paper, the optimal installation position of pitot tube for measuring L-type pitot coefficient in wind tunnel is studied. By analyzing the calculation formula of pitot tube coefficient, it is concluded that the influencing factor of pitot tube coefficient measurement is the difference between pitot tube total pressure and static pressure. The CFD simulation of the wind speed field near the pitot tube in the wind tunnel shows that the position that may affect the measurement results is close to the side wall of the wind tunnel. Experiments are carried out at these positions. The pitot tube is installed at different positions in the wind tunnel, the differential pressure value is measured, and the area with small differential pressure change is observed. It is concluded that the optimal installation position for pitot tube measurement is the middle position more than 50mm away from the standard pitot tube and more than 50mm away from the side wall of the wind tunnel.","PeriodicalId":289132,"journal":{"name":"2021 IEEE 15th International Conference on Electronic Measurement & Instruments (ICEMI)","volume":"254 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study on the Optimal Installation Position of L-type Pitot Tube During Calibration\",\"authors\":\"Xingen Liu, Xia Li, Lingshan Yang, Weihui Zhou, Yang Xiang\",\"doi\":\"10.1109/ICEMI52946.2021.9679525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the optimal installation position of pitot tube for measuring L-type pitot coefficient in wind tunnel is studied. By analyzing the calculation formula of pitot tube coefficient, it is concluded that the influencing factor of pitot tube coefficient measurement is the difference between pitot tube total pressure and static pressure. The CFD simulation of the wind speed field near the pitot tube in the wind tunnel shows that the position that may affect the measurement results is close to the side wall of the wind tunnel. Experiments are carried out at these positions. The pitot tube is installed at different positions in the wind tunnel, the differential pressure value is measured, and the area with small differential pressure change is observed. It is concluded that the optimal installation position for pitot tube measurement is the middle position more than 50mm away from the standard pitot tube and more than 50mm away from the side wall of the wind tunnel.\",\"PeriodicalId\":289132,\"journal\":{\"name\":\"2021 IEEE 15th International Conference on Electronic Measurement & Instruments (ICEMI)\",\"volume\":\"254 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 15th International Conference on Electronic Measurement & Instruments (ICEMI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMI52946.2021.9679525\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 15th International Conference on Electronic Measurement & Instruments (ICEMI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMI52946.2021.9679525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文对风洞中测量l型皮托管系数时皮托管的最佳安装位置进行了研究。通过对皮托管系数计算公式的分析,得出皮托管系数测量的影响因素是皮托管总压与静压之差。对风洞中皮托管附近风速场的CFD模拟表明,可能影响测量结果的位置靠近风洞侧壁。在这些位置进行实验。在风洞内不同位置安装皮托管,测量压差值,观察压差变化较小的区域。得出皮托管测量的最佳安装位置为距离标准皮托管50mm以上、距离风洞侧壁50mm以上的中间位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on the Optimal Installation Position of L-type Pitot Tube During Calibration
In this paper, the optimal installation position of pitot tube for measuring L-type pitot coefficient in wind tunnel is studied. By analyzing the calculation formula of pitot tube coefficient, it is concluded that the influencing factor of pitot tube coefficient measurement is the difference between pitot tube total pressure and static pressure. The CFD simulation of the wind speed field near the pitot tube in the wind tunnel shows that the position that may affect the measurement results is close to the side wall of the wind tunnel. Experiments are carried out at these positions. The pitot tube is installed at different positions in the wind tunnel, the differential pressure value is measured, and the area with small differential pressure change is observed. It is concluded that the optimal installation position for pitot tube measurement is the middle position more than 50mm away from the standard pitot tube and more than 50mm away from the side wall of the wind tunnel.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信