电力线监测用智能反射仪的计量分析

A. Shilin, A. Shilin, N. Kuznetsova, D. N. Avdeyuk
{"title":"电力线监测用智能反射仪的计量分析","authors":"A. Shilin, A. Shilin, N. Kuznetsova, D. N. Avdeyuk","doi":"10.14489/td.2022.11.pp.036-045","DOIUrl":null,"url":null,"abstract":"The article provides an analysis of the sources of errors of reflectometers. The main error of reflectometers is the methodological component, which is determined by the error of setting the phase velocity of the pulse. The phase velocity of the pulse depends on various external factors. The instrumental component of the error is due to the instability of the reflected pulse shape and the presence of noise in the signal. Based on metrological analysis, an intelligent reflectometer was developed for monitoring overhead power transmission lines. The developed reflectometer contains blocks and nodes to compensate and reduce the main components of the total error. The developed reflectometer makes it possible to increase the accuracy of determining the accident site and reduce the recovery time of the line, and, consequently, increase the reliability of power supply.","PeriodicalId":432853,"journal":{"name":"Kontrol'. Diagnostika","volume":"342 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"METROLOGICAL ANALYSIS OF AN INTELLIGENT REFLECTOMETER FOR MONITORING POWER LINES\",\"authors\":\"A. Shilin, A. Shilin, N. Kuznetsova, D. N. Avdeyuk\",\"doi\":\"10.14489/td.2022.11.pp.036-045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article provides an analysis of the sources of errors of reflectometers. The main error of reflectometers is the methodological component, which is determined by the error of setting the phase velocity of the pulse. The phase velocity of the pulse depends on various external factors. The instrumental component of the error is due to the instability of the reflected pulse shape and the presence of noise in the signal. Based on metrological analysis, an intelligent reflectometer was developed for monitoring overhead power transmission lines. The developed reflectometer contains blocks and nodes to compensate and reduce the main components of the total error. The developed reflectometer makes it possible to increase the accuracy of determining the accident site and reduce the recovery time of the line, and, consequently, increase the reliability of power supply.\",\"PeriodicalId\":432853,\"journal\":{\"name\":\"Kontrol'. Diagnostika\",\"volume\":\"342 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kontrol'. Diagnostika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14489/td.2022.11.pp.036-045\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kontrol'. Diagnostika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14489/td.2022.11.pp.036-045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文分析了反射计的误差来源。反射计的主要误差是方法分量,它是由设定脉冲相速度的误差决定的。脉冲的相速度取决于各种外部因素。误差的仪器成分是由于反射脉冲形状的不稳定性和信号中噪声的存在。在计量分析的基础上,研制了一种用于架空输电线路监测的智能反射仪。所开发的反射计包含块和节点,以补偿和减小总误差的主要分量。所研制的反射仪可以提高事故现场的确定精度,缩短线路的恢复时间,从而提高供电的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
METROLOGICAL ANALYSIS OF AN INTELLIGENT REFLECTOMETER FOR MONITORING POWER LINES
The article provides an analysis of the sources of errors of reflectometers. The main error of reflectometers is the methodological component, which is determined by the error of setting the phase velocity of the pulse. The phase velocity of the pulse depends on various external factors. The instrumental component of the error is due to the instability of the reflected pulse shape and the presence of noise in the signal. Based on metrological analysis, an intelligent reflectometer was developed for monitoring overhead power transmission lines. The developed reflectometer contains blocks and nodes to compensate and reduce the main components of the total error. The developed reflectometer makes it possible to increase the accuracy of determining the accident site and reduce the recovery time of the line, and, consequently, increase the reliability of power supply.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信