高压汽轮、水轮发电机定子槽均匀场电极与绝缘系统

V. Kuzmin, L.L. Khaimovitch
{"title":"高压汽轮、水轮发电机定子槽均匀场电极与绝缘系统","authors":"V. Kuzmin, L.L. Khaimovitch","doi":"10.1109/EEIC.2001.965610","DOIUrl":null,"url":null,"abstract":"The system of electrodes of the uniform field of the slot of high-voltage turbo- and hydrogenerators is designed and investigated. This system is determined as a result of the investigation of the mutual distribution of equigradient and equipotential lines of the electric field in the interelectrode space of the stator slot. By applying the profile of the uniform field, the nonuniform part of the field with high strength is excluded. It helps to increase the insulation strength. \"Life term\" of the bars with the full field reduction was higher than for similar bars with a partial reduction. The system of electrodes of the uniform field is designed for the stator winding of turbogenerators at the rated voltage 36-60 kV and for the hydrogenerators of special manufacture at the extra high rated voltage 220 kV.","PeriodicalId":228071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","volume":"324 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The system of electrodes of the uniform field of stator slot and the insulation of high-voltage turbo- and hydrogenerators\",\"authors\":\"V. Kuzmin, L.L. Khaimovitch\",\"doi\":\"10.1109/EEIC.2001.965610\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The system of electrodes of the uniform field of the slot of high-voltage turbo- and hydrogenerators is designed and investigated. This system is determined as a result of the investigation of the mutual distribution of equigradient and equipotential lines of the electric field in the interelectrode space of the stator slot. By applying the profile of the uniform field, the nonuniform part of the field with high strength is excluded. It helps to increase the insulation strength. \\\"Life term\\\" of the bars with the full field reduction was higher than for similar bars with a partial reduction. The system of electrodes of the uniform field is designed for the stator winding of turbogenerators at the rated voltage 36-60 kV and for the hydrogenerators of special manufacture at the extra high rated voltage 220 kV.\",\"PeriodicalId\":228071,\"journal\":{\"name\":\"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)\",\"volume\":\"324 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEIC.2001.965610\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2001.965610","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对高压水轮汽轮发电机槽均匀场电极系统进行了设计和研究。该系统是通过研究定子槽电极间空间电场的等电位线和等电位线的相互分布而确定的。采用均匀场的剖面,排除了高强度的非均匀场。它有助于提高绝缘强度。全场还原的棒材的“寿命”高于部分还原的棒材。均匀场电极系统是为额定电压36 ~ 60kv的汽轮发电机定子绕组和特殊制造的特高额定电压220kv的水轮发电机设计的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The system of electrodes of the uniform field of stator slot and the insulation of high-voltage turbo- and hydrogenerators
The system of electrodes of the uniform field of the slot of high-voltage turbo- and hydrogenerators is designed and investigated. This system is determined as a result of the investigation of the mutual distribution of equigradient and equipotential lines of the electric field in the interelectrode space of the stator slot. By applying the profile of the uniform field, the nonuniform part of the field with high strength is excluded. It helps to increase the insulation strength. "Life term" of the bars with the full field reduction was higher than for similar bars with a partial reduction. The system of electrodes of the uniform field is designed for the stator winding of turbogenerators at the rated voltage 36-60 kV and for the hydrogenerators of special manufacture at the extra high rated voltage 220 kV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信