{"title":"前列腺近距离放射治疗技术综述","authors":"Yanlei Li,&nbsp;Chenguang Yang,&nbsp;Amit Bahl,&nbsp;Raj Persad,&nbsp;Chris Melhuish","doi":"10.1049/ccs2.12067","DOIUrl":null,"url":null,"abstract":"<p>Prostate brachytherapy is a validated treatment for prostate cancer. During the procedure, the accuracy of needle placement is critical to the treatment’s effectiveness. However, the inserted needle could deflect from the preset trajectory because of the needle deflection, tissue shifting caused by the interaction between the needle and soft tissue, as well as the effects of pre-inserted needles. There are significant challenges in needle placement areas, especially in prostate brachytherapy, because multiple needles are required for the effectiveness of radiation. To overcome these limitations, relevant research is carried out in mechanical, computer science, and material science areas. With the development of surgical robotics, researchers are also exploring the possibilities of raising the accuracy of needle placement with surgical-assisted robotics. This study provides a review over the last 3 decades in each of the component research areas that constitutes a surgical robotics system, including needle steering approaches, needle-tissue deformation models, path planning algorithms and different automatic level surgical robotics systems used for prostate cancer treatment, especially prostate brachytherapy. Further directions for researchers are also suggested.</p>","PeriodicalId":33652,"journal":{"name":"Cognitive Computation and Systems","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/ccs2.12067","citationCount":"6","resultStr":"{\"title\":\"A review on the techniques used in prostate brachytherapy\",\"authors\":\"Yanlei Li,&nbsp;Chenguang Yang,&nbsp;Amit Bahl,&nbsp;Raj Persad,&nbsp;Chris Melhuish\",\"doi\":\"10.1049/ccs2.12067\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Prostate brachytherapy is a validated treatment for prostate cancer. During the procedure, the accuracy of needle placement is critical to the treatment’s effectiveness. However, the inserted needle could deflect from the preset trajectory because of the needle deflection, tissue shifting caused by the interaction between the needle and soft tissue, as well as the effects of pre-inserted needles. There are significant challenges in needle placement areas, especially in prostate brachytherapy, because multiple needles are required for the effectiveness of radiation. To overcome these limitations, relevant research is carried out in mechanical, computer science, and material science areas. With the development of surgical robotics, researchers are also exploring the possibilities of raising the accuracy of needle placement with surgical-assisted robotics. This study provides a review over the last 3 decades in each of the component research areas that constitutes a surgical robotics system, including needle steering approaches, needle-tissue deformation models, path planning algorithms and different automatic level surgical robotics systems used for prostate cancer treatment, especially prostate brachytherapy. Further directions for researchers are also suggested.</p>\",\"PeriodicalId\":33652,\"journal\":{\"name\":\"Cognitive Computation and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/ccs2.12067\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cognitive Computation and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/ccs2.12067\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cognitive Computation and Systems","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/ccs2.12067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE","Score":null,"Total":0}
引用次数: 6

摘要

前列腺近距离放射治疗是一种有效的前列腺癌治疗方法。在手术过程中,针头放置的准确性对治疗的有效性至关重要。然而,由于针的偏转、针与软组织相互作用引起的组织移位以及预插针的影响,插入的针可能偏离预定的轨迹。在针头放置领域,特别是在前列腺近距离放射治疗中,存在重大挑战,因为放射的有效性需要多个针头。为了克服这些限制,相关的研究在机械、计算机科学和材料科学领域进行。随着手术机器人技术的发展,研究人员也在探索利用手术辅助机器人技术提高针头放置精度的可能性。本研究综述了过去30年来构成手术机器人系统的每个组成部分的研究领域,包括针导向方法、针组织变形模型、路径规划算法和用于前列腺癌治疗的不同自动水平的手术机器人系统,特别是前列腺近距离治疗。并提出了今后研究的方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A review on the techniques used in prostate brachytherapy

A review on the techniques used in prostate brachytherapy

Prostate brachytherapy is a validated treatment for prostate cancer. During the procedure, the accuracy of needle placement is critical to the treatment’s effectiveness. However, the inserted needle could deflect from the preset trajectory because of the needle deflection, tissue shifting caused by the interaction between the needle and soft tissue, as well as the effects of pre-inserted needles. There are significant challenges in needle placement areas, especially in prostate brachytherapy, because multiple needles are required for the effectiveness of radiation. To overcome these limitations, relevant research is carried out in mechanical, computer science, and material science areas. With the development of surgical robotics, researchers are also exploring the possibilities of raising the accuracy of needle placement with surgical-assisted robotics. This study provides a review over the last 3 decades in each of the component research areas that constitutes a surgical robotics system, including needle steering approaches, needle-tissue deformation models, path planning algorithms and different automatic level surgical robotics systems used for prostate cancer treatment, especially prostate brachytherapy. Further directions for researchers are also suggested.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cognitive Computation and Systems
Cognitive Computation and Systems Computer Science-Computer Science Applications
CiteScore
2.50
自引率
0.00%
发文量
39
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信