静电驱动硅膜,通过微泵控制注入流体的体积

N. Benmoussa, A. Guen, B. Bouazza, R. Otmani
{"title":"静电驱动硅膜,通过微泵控制注入流体的体积","authors":"N. Benmoussa, A. Guen, B. Bouazza, R. Otmani","doi":"10.1109/NAWDMPV.2014.6997607","DOIUrl":null,"url":null,"abstract":"This paper is to study the phenomenon of electrostatic actuation of a silicon membrane for injecting a sufficient quantity of fluid and in particular medication with a micro pump. The latter becomes a void of first choice for the treatment of diseases such as diabetes that requires the use of a syringe for insulin injection. With the development of MEMS technology, the injection of insulin is transmitted through a micro pump located outside the human body and connected to a subcutaneous cannula to control the dosage depending on the need body. The idea is to take the patient's blood glucose and compared with a reference value. Based on the obtained difference, an electronic system calculates the volume of insulin and the number of units required to be injected to stabilize blood glucose levels. The micropump is constituted by a silicon membrane electrostatically actuated by a DC voltage V. This actuation causes deformation of the membrane leading to the opening of the first micro valve and the introduction of a unit volume in the chamber internal micro pump through the first pipe. The annulment of the voltage V leads to the return of the membrane at equilibrium. This causes the closure of the first valve and the opening of the second micro valve which will inject the fluid into the second pipe.","PeriodicalId":149945,"journal":{"name":"2014 North African Workshop on Dielectic Materials for Photovoltaic Systems (NAWDMPV)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrostatic actuation of a silicon membrane to control the injected fluid volume by a micro pump\",\"authors\":\"N. Benmoussa, A. Guen, B. Bouazza, R. Otmani\",\"doi\":\"10.1109/NAWDMPV.2014.6997607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper is to study the phenomenon of electrostatic actuation of a silicon membrane for injecting a sufficient quantity of fluid and in particular medication with a micro pump. The latter becomes a void of first choice for the treatment of diseases such as diabetes that requires the use of a syringe for insulin injection. With the development of MEMS technology, the injection of insulin is transmitted through a micro pump located outside the human body and connected to a subcutaneous cannula to control the dosage depending on the need body. The idea is to take the patient's blood glucose and compared with a reference value. Based on the obtained difference, an electronic system calculates the volume of insulin and the number of units required to be injected to stabilize blood glucose levels. The micropump is constituted by a silicon membrane electrostatically actuated by a DC voltage V. This actuation causes deformation of the membrane leading to the opening of the first micro valve and the introduction of a unit volume in the chamber internal micro pump through the first pipe. The annulment of the voltage V leads to the return of the membrane at equilibrium. This causes the closure of the first valve and the opening of the second micro valve which will inject the fluid into the second pipe.\",\"PeriodicalId\":149945,\"journal\":{\"name\":\"2014 North African Workshop on Dielectic Materials for Photovoltaic Systems (NAWDMPV)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 North African Workshop on Dielectic Materials for Photovoltaic Systems (NAWDMPV)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAWDMPV.2014.6997607\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North African Workshop on Dielectic Materials for Photovoltaic Systems (NAWDMPV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAWDMPV.2014.6997607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究静电驱动硅膜的现象,用微泵注入足量的液体,特别是药物。后者成为治疗糖尿病等需要使用注射器注射胰岛素的疾病的首选。随着MEMS技术的发展,胰岛素的注射通过位于人体外部的微型泵传输,并连接到皮下插管,根据需要的身体控制剂量。这个想法是取病人的血糖,并与参考值进行比较。根据得到的差值,电子系统计算胰岛素的体积和稳定血糖水平所需注射的单位数。微泵由直流电压v静电驱动的硅膜构成,该驱动引起膜的变形,导致第一微阀打开,并通过第一管道将单位体积引入腔室内部微泵。电压V的取消导致膜回到平衡状态。这导致第一个阀门关闭,第二个微型阀门打开,将流体注入第二个管道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrostatic actuation of a silicon membrane to control the injected fluid volume by a micro pump
This paper is to study the phenomenon of electrostatic actuation of a silicon membrane for injecting a sufficient quantity of fluid and in particular medication with a micro pump. The latter becomes a void of first choice for the treatment of diseases such as diabetes that requires the use of a syringe for insulin injection. With the development of MEMS technology, the injection of insulin is transmitted through a micro pump located outside the human body and connected to a subcutaneous cannula to control the dosage depending on the need body. The idea is to take the patient's blood glucose and compared with a reference value. Based on the obtained difference, an electronic system calculates the volume of insulin and the number of units required to be injected to stabilize blood glucose levels. The micropump is constituted by a silicon membrane electrostatically actuated by a DC voltage V. This actuation causes deformation of the membrane leading to the opening of the first micro valve and the introduction of a unit volume in the chamber internal micro pump through the first pipe. The annulment of the voltage V leads to the return of the membrane at equilibrium. This causes the closure of the first valve and the opening of the second micro valve which will inject the fluid into the second pipe.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信