外渗蛋白的天然荧光

Anna Miller-Larsson, Ralph Brattsand
{"title":"外渗蛋白的天然荧光","authors":"Anna Miller-Larsson,&nbsp;Ralph Brattsand","doi":"10.1016/0160-5402(91)90015-W","DOIUrl":null,"url":null,"abstract":"<div><p>Macromolecular vascular leakage into rat tracheal lumen is quantified by a new method that does not require the administration of an exogenous macromolecular tracer or dye to the animals. The magnitude of vascular leakage is determined by the concentration of extravasated plasma proteins measured by their native fluorescence and assayed against diluted plasma. Native fluorescence of proteins (PNF), when excited at 295 nm and measured at 340 nm, is almost exclusively due to tryptophan fluorescence. The PNF assay can be used in the range of protein concentration of 0.1–120 μg/mL. The results obtained in the PNF assay were found to be equivalent to the results from two other conventional assays where fluorescent or radioactive albumin was used as the external macromolecular tracer.</p></div>","PeriodicalId":16819,"journal":{"name":"Journal of pharmacological methods","volume":"25 3","pages":"Pages 251-262"},"PeriodicalIF":0.0000,"publicationDate":"1991-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0160-5402(91)90015-W","citationCount":"6","resultStr":"{\"title\":\"Native fluorescence of extravasated proteins\",\"authors\":\"Anna Miller-Larsson,&nbsp;Ralph Brattsand\",\"doi\":\"10.1016/0160-5402(91)90015-W\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Macromolecular vascular leakage into rat tracheal lumen is quantified by a new method that does not require the administration of an exogenous macromolecular tracer or dye to the animals. The magnitude of vascular leakage is determined by the concentration of extravasated plasma proteins measured by their native fluorescence and assayed against diluted plasma. Native fluorescence of proteins (PNF), when excited at 295 nm and measured at 340 nm, is almost exclusively due to tryptophan fluorescence. The PNF assay can be used in the range of protein concentration of 0.1–120 μg/mL. The results obtained in the PNF assay were found to be equivalent to the results from two other conventional assays where fluorescent or radioactive albumin was used as the external macromolecular tracer.</p></div>\",\"PeriodicalId\":16819,\"journal\":{\"name\":\"Journal of pharmacological methods\",\"volume\":\"25 3\",\"pages\":\"Pages 251-262\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0160-5402(91)90015-W\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacological methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/016054029190015W\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/016054029190015W","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

采用一种不需要给动物施用外源性大分子示踪剂或染料的新方法,对大鼠气管腔内的大分子血管渗漏进行了定量分析。血管渗漏的大小是由外渗血浆蛋白的浓度决定的,用它们的天然荧光测量,并对稀释的血浆进行测定。在295 nm激发和340 nm测量时,蛋白质(PNF)的天然荧光几乎完全是由于色氨酸的荧光。PNF法适用于0.1 ~ 120 μg/mL的蛋白浓度范围。在PNF试验中获得的结果被发现与使用荧光或放射性白蛋白作为外部大分子示踪剂的其他两种常规试验的结果相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Native fluorescence of extravasated proteins

Macromolecular vascular leakage into rat tracheal lumen is quantified by a new method that does not require the administration of an exogenous macromolecular tracer or dye to the animals. The magnitude of vascular leakage is determined by the concentration of extravasated plasma proteins measured by their native fluorescence and assayed against diluted plasma. Native fluorescence of proteins (PNF), when excited at 295 nm and measured at 340 nm, is almost exclusively due to tryptophan fluorescence. The PNF assay can be used in the range of protein concentration of 0.1–120 μg/mL. The results obtained in the PNF assay were found to be equivalent to the results from two other conventional assays where fluorescent or radioactive albumin was used as the external macromolecular tracer.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信