L. F. de F Gutierres, L. Mariotto, G. Cardoso, F. Loose
{"title":"基于逆变器的分布式发电系统重合闸-熔断器协调保护","authors":"L. F. de F Gutierres, L. Mariotto, G. Cardoso, F. Loose","doi":"10.1109/UPEC.2015.7339778","DOIUrl":null,"url":null,"abstract":"This paper presents a novel recloser-fuse coordination protection for inverter-based distributed generation systems based on the use of RMS current comparators. In real-time, these comparators are responsible for analyzing current magnitude in upstream and downstream network directions; identify faults; and assess the recloser-fuse coordination status based on critical margins identified by the protection methodology. Once a mis-coordination is detected, some distributed generation units are strategically disconnected from the distribution network by gate turn-off thyristors. As a result of this action, short-circuit current is reduced to a satisfactory level, restoring the coordination between recloser and fuses in the grid. The proposed methodology has been implemented in a 12.47-kV grid with interconnection of 10 MW and 15 MW wind farms. Simulations have been carried out in ATP/EMTP. Significantly, the approach contributes to the adequacy and modernization of distribution systems with considerable tendency of distributed generation insertion.","PeriodicalId":446482,"journal":{"name":"2015 50th International Universities Power Engineering Conference (UPEC)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Recloser-fuse coordination protection for inverter-based distributed generation systems\",\"authors\":\"L. F. de F Gutierres, L. Mariotto, G. Cardoso, F. Loose\",\"doi\":\"10.1109/UPEC.2015.7339778\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel recloser-fuse coordination protection for inverter-based distributed generation systems based on the use of RMS current comparators. In real-time, these comparators are responsible for analyzing current magnitude in upstream and downstream network directions; identify faults; and assess the recloser-fuse coordination status based on critical margins identified by the protection methodology. Once a mis-coordination is detected, some distributed generation units are strategically disconnected from the distribution network by gate turn-off thyristors. As a result of this action, short-circuit current is reduced to a satisfactory level, restoring the coordination between recloser and fuses in the grid. The proposed methodology has been implemented in a 12.47-kV grid with interconnection of 10 MW and 15 MW wind farms. Simulations have been carried out in ATP/EMTP. Significantly, the approach contributes to the adequacy and modernization of distribution systems with considerable tendency of distributed generation insertion.\",\"PeriodicalId\":446482,\"journal\":{\"name\":\"2015 50th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 50th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2015.7339778\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 50th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2015.7339778","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Recloser-fuse coordination protection for inverter-based distributed generation systems
This paper presents a novel recloser-fuse coordination protection for inverter-based distributed generation systems based on the use of RMS current comparators. In real-time, these comparators are responsible for analyzing current magnitude in upstream and downstream network directions; identify faults; and assess the recloser-fuse coordination status based on critical margins identified by the protection methodology. Once a mis-coordination is detected, some distributed generation units are strategically disconnected from the distribution network by gate turn-off thyristors. As a result of this action, short-circuit current is reduced to a satisfactory level, restoring the coordination between recloser and fuses in the grid. The proposed methodology has been implemented in a 12.47-kV grid with interconnection of 10 MW and 15 MW wind farms. Simulations have been carried out in ATP/EMTP. Significantly, the approach contributes to the adequacy and modernization of distribution systems with considerable tendency of distributed generation insertion.