{"title":"气体传感用超低功耗热板的研制","authors":"I. Elmi, S. Zampolli, E. Cozzani, M. Passini, G. Cardinali, M. Severi","doi":"10.1109/ICSENS.2007.355767","DOIUrl":null,"url":null,"abstract":"This paper deals with the development of state-of-the-art ultra low power (ULP) consumption hotplates to be used as metal oxide gas sensor substrates. Several types of ULP devices, differing in shape and size, have been fabricated with the same front-side bulk silicon micromachining technology. Details on the device design and on the fabrication processes are provided. The ULP hotplates functional behavior was thoroughly investigated. Typical results on measurements of the hotplate temperature versus applied power are reported. A very satisfactory value of 8.9 mW at 400degC can be highlighted. Transient temperature responses and evaluation of the hotplate thermal time constant were also carried out.","PeriodicalId":233838,"journal":{"name":"2006 5th IEEE Conference on Sensors","volume":"48 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Development of Ultra Low Power Consumption Hotplates for Gas Sensing Applications\",\"authors\":\"I. Elmi, S. Zampolli, E. Cozzani, M. Passini, G. Cardinali, M. Severi\",\"doi\":\"10.1109/ICSENS.2007.355767\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the development of state-of-the-art ultra low power (ULP) consumption hotplates to be used as metal oxide gas sensor substrates. Several types of ULP devices, differing in shape and size, have been fabricated with the same front-side bulk silicon micromachining technology. Details on the device design and on the fabrication processes are provided. The ULP hotplates functional behavior was thoroughly investigated. Typical results on measurements of the hotplate temperature versus applied power are reported. A very satisfactory value of 8.9 mW at 400degC can be highlighted. Transient temperature responses and evaluation of the hotplate thermal time constant were also carried out.\",\"PeriodicalId\":233838,\"journal\":{\"name\":\"2006 5th IEEE Conference on Sensors\",\"volume\":\"48 3\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 5th IEEE Conference on Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2007.355767\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 5th IEEE Conference on Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2007.355767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

本文讨论了用于金属氧化物气体传感器基板的超低功耗(ULP)消耗热板的发展。几种不同形状和尺寸的ULP器件已经用相同的前侧体硅微加工技术制造出来。提供了有关器件设计和制造工艺的详细信息。对ULP热板的功能行为进行了深入的研究。报告了热板温度与施加功率的典型测量结果。在400°c时,可以突出显示一个非常令人满意的8.9 mW值。进行了瞬态温度响应和热板热时间常数的计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of Ultra Low Power Consumption Hotplates for Gas Sensing Applications
This paper deals with the development of state-of-the-art ultra low power (ULP) consumption hotplates to be used as metal oxide gas sensor substrates. Several types of ULP devices, differing in shape and size, have been fabricated with the same front-side bulk silicon micromachining technology. Details on the device design and on the fabrication processes are provided. The ULP hotplates functional behavior was thoroughly investigated. Typical results on measurements of the hotplate temperature versus applied power are reported. A very satisfactory value of 8.9 mW at 400degC can be highlighted. Transient temperature responses and evaluation of the hotplate thermal time constant were also carried out.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信