{"title":"空气-水发生器进口侧风机的入风速度对淡水质量的影响","authors":"M. Mirmanto, M. Wirawan, Gagas Irhami","doi":"10.30574/gjeta.2023.16.2.0160","DOIUrl":null,"url":null,"abstract":"The air-water generator is a promising device to provide freshwater in the future. However, the machine still produces less freshwater; hence, a study of the effect of air velocity with a fan installed at the entrance of a simple air-water generator on the freshwater mass was conducted under environmental conditions. The air velocities varied were 4 m/s, 5 m/s, and 6 m/s. The air-water generator was made from a refrigeration machine system using R134a refrigerant as the working fluid. The compressor specification was 1 PK rotary type. The results show that the highest average freshwater mass obtained is 1241 g for 7 hours, the highest COP was 4.72, and the highest total heat transfer rate is 208.21 J/s.","PeriodicalId":402125,"journal":{"name":"Global Journal of Engineering and Technology Advances","volume":"30 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The influence of the incoming air velocity with the fan on the inlet side of an air-water generator on the freshwater mass\",\"authors\":\"M. Mirmanto, M. Wirawan, Gagas Irhami\",\"doi\":\"10.30574/gjeta.2023.16.2.0160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The air-water generator is a promising device to provide freshwater in the future. However, the machine still produces less freshwater; hence, a study of the effect of air velocity with a fan installed at the entrance of a simple air-water generator on the freshwater mass was conducted under environmental conditions. The air velocities varied were 4 m/s, 5 m/s, and 6 m/s. The air-water generator was made from a refrigeration machine system using R134a refrigerant as the working fluid. The compressor specification was 1 PK rotary type. The results show that the highest average freshwater mass obtained is 1241 g for 7 hours, the highest COP was 4.72, and the highest total heat transfer rate is 208.21 J/s.\",\"PeriodicalId\":402125,\"journal\":{\"name\":\"Global Journal of Engineering and Technology Advances\",\"volume\":\"30 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Journal of Engineering and Technology Advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30574/gjeta.2023.16.2.0160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Journal of Engineering and Technology Advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30574/gjeta.2023.16.2.0160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The influence of the incoming air velocity with the fan on the inlet side of an air-water generator on the freshwater mass
The air-water generator is a promising device to provide freshwater in the future. However, the machine still produces less freshwater; hence, a study of the effect of air velocity with a fan installed at the entrance of a simple air-water generator on the freshwater mass was conducted under environmental conditions. The air velocities varied were 4 m/s, 5 m/s, and 6 m/s. The air-water generator was made from a refrigeration machine system using R134a refrigerant as the working fluid. The compressor specification was 1 PK rotary type. The results show that the highest average freshwater mass obtained is 1241 g for 7 hours, the highest COP was 4.72, and the highest total heat transfer rate is 208.21 J/s.