Marc Foxall, R. Giussani, M. Seltzer-Grant, Blake Sheen
{"title":"油气高压资产局部放电状态在线监测策略优化","authors":"Marc Foxall, R. Giussani, M. Seltzer-Grant, Blake Sheen","doi":"10.23919/PCICEUROPE.2018.8491404","DOIUrl":null,"url":null,"abstract":"With lower-for-longer wholesale price conditions in the oil and gas market, asset optimisation is now more critical than ever. To avoid unplanned outages, and extend asset lifecycles, condition-based maintenance can be used to prioritise maintenance and/or repair. The early detection of medium and high voltage insulation faults can maximise network safety, improve reliability and help to implement asset extension life programs.On-line partial discharge (OLPD) detection and monitoring is adopted and recognised as one of the best, non-intrusive, early warning indicator of insulation degradation in MV/HV networks.This paper describes industry approaches for OLPD monitoring showing the benefits and results of using such technology. Strategies for condition-based maintenance are discussed along with how data can be used strategically in the operation of the network, including network reconfiguration, maintenance prioritisation, refurbishment and/or replacement.A case study where effective OLPD monitoring of critical 11 kV generators in a downstream European oil refinery was implemented and allowed informed decisions to be made prior to unplanned outages is presented.","PeriodicalId":137620,"journal":{"name":"2018 Petroleum and Chemical Industry Conference Europe (PCIC Europe)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"ON-LINE PARTIAL DISCHARGE CONDITION MONITORING STRATEGIES FOR OIL AND GAS HIGH VOLTAGE ASSETS OPTIMISATION\",\"authors\":\"Marc Foxall, R. Giussani, M. Seltzer-Grant, Blake Sheen\",\"doi\":\"10.23919/PCICEUROPE.2018.8491404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With lower-for-longer wholesale price conditions in the oil and gas market, asset optimisation is now more critical than ever. To avoid unplanned outages, and extend asset lifecycles, condition-based maintenance can be used to prioritise maintenance and/or repair. The early detection of medium and high voltage insulation faults can maximise network safety, improve reliability and help to implement asset extension life programs.On-line partial discharge (OLPD) detection and monitoring is adopted and recognised as one of the best, non-intrusive, early warning indicator of insulation degradation in MV/HV networks.This paper describes industry approaches for OLPD monitoring showing the benefits and results of using such technology. Strategies for condition-based maintenance are discussed along with how data can be used strategically in the operation of the network, including network reconfiguration, maintenance prioritisation, refurbishment and/or replacement.A case study where effective OLPD monitoring of critical 11 kV generators in a downstream European oil refinery was implemented and allowed informed decisions to be made prior to unplanned outages is presented.\",\"PeriodicalId\":137620,\"journal\":{\"name\":\"2018 Petroleum and Chemical Industry Conference Europe (PCIC Europe)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Petroleum and Chemical Industry Conference Europe (PCIC Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/PCICEUROPE.2018.8491404\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Petroleum and Chemical Industry Conference Europe (PCIC Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/PCICEUROPE.2018.8491404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ON-LINE PARTIAL DISCHARGE CONDITION MONITORING STRATEGIES FOR OIL AND GAS HIGH VOLTAGE ASSETS OPTIMISATION
With lower-for-longer wholesale price conditions in the oil and gas market, asset optimisation is now more critical than ever. To avoid unplanned outages, and extend asset lifecycles, condition-based maintenance can be used to prioritise maintenance and/or repair. The early detection of medium and high voltage insulation faults can maximise network safety, improve reliability and help to implement asset extension life programs.On-line partial discharge (OLPD) detection and monitoring is adopted and recognised as one of the best, non-intrusive, early warning indicator of insulation degradation in MV/HV networks.This paper describes industry approaches for OLPD monitoring showing the benefits and results of using such technology. Strategies for condition-based maintenance are discussed along with how data can be used strategically in the operation of the network, including network reconfiguration, maintenance prioritisation, refurbishment and/or replacement.A case study where effective OLPD monitoring of critical 11 kV generators in a downstream European oil refinery was implemented and allowed informed decisions to be made prior to unplanned outages is presented.