{"title":"一种将三相电力变压器模型纳入配电系统潮流分析的新方法","authors":"R. Gianto, Purwoharjono Purwoharjono","doi":"10.11591/IJAPE.V10.I3.PP262-270","DOIUrl":null,"url":null,"abstract":"This paper proposes a new and simple method to incorporate three-phase power transformer model into distribution system load flow (DSLF) analysis. The objective of the present work is to find a robust and efficient technique for modeling and integrating power transformer in the DSLF analysis. The proposed transformer model is derived based on nodal admittance matrix and formulated by using the symmetrical component theory. Load flow formulation in terms of branch currents and nodal voltages is also proposed in this paper to enable integrating the model into the DSLF analysis. Singularity that makes the calculations in forward/backward sweep (FBS) algorithm is difficult to be carried out. It can be avoided in the method. The proposed model is verified by using the standard IEEE test system.","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new method to incorporate three-phase power transformer model into distribution system load flow analysis\",\"authors\":\"R. Gianto, Purwoharjono Purwoharjono\",\"doi\":\"10.11591/IJAPE.V10.I3.PP262-270\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new and simple method to incorporate three-phase power transformer model into distribution system load flow (DSLF) analysis. The objective of the present work is to find a robust and efficient technique for modeling and integrating power transformer in the DSLF analysis. The proposed transformer model is derived based on nodal admittance matrix and formulated by using the symmetrical component theory. Load flow formulation in terms of branch currents and nodal voltages is also proposed in this paper to enable integrating the model into the DSLF analysis. Singularity that makes the calculations in forward/backward sweep (FBS) algorithm is difficult to be carried out. It can be avoided in the method. The proposed model is verified by using the standard IEEE test system.\",\"PeriodicalId\":280098,\"journal\":{\"name\":\"International Journal of Applied Power Engineering\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/IJAPE.V10.I3.PP262-270\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/IJAPE.V10.I3.PP262-270","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new method to incorporate three-phase power transformer model into distribution system load flow analysis
This paper proposes a new and simple method to incorporate three-phase power transformer model into distribution system load flow (DSLF) analysis. The objective of the present work is to find a robust and efficient technique for modeling and integrating power transformer in the DSLF analysis. The proposed transformer model is derived based on nodal admittance matrix and formulated by using the symmetrical component theory. Load flow formulation in terms of branch currents and nodal voltages is also proposed in this paper to enable integrating the model into the DSLF analysis. Singularity that makes the calculations in forward/backward sweep (FBS) algorithm is difficult to be carried out. It can be avoided in the method. The proposed model is verified by using the standard IEEE test system.