{"title":"T型热电偶各热元件的不均匀性","authors":"Y. Tamura, C. Uematsu","doi":"10.1109/SICE.2002.1195314","DOIUrl":null,"url":null,"abstract":"Some studies on inhomogeneity of type K thermocouples were reported, but inhomogeneity of each thermoelement of the thermocouples was not reported. We studied inhomogeneity of each thermoelement of T thermocouples and verified experimentally that inhomogeneity of each thermoelement can be measured by using grounded-junction sheathed thermocouples. After annealing at 400 degrees Celsius and 250 hours, the positive leg (Copper) of T thermocouples did not reveal no inhomogeneity but the negative leg(Constantan) revealed some inhomogeneity.","PeriodicalId":301855,"journal":{"name":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inhomogeneity of each thermoelements of type T thermocouples\",\"authors\":\"Y. Tamura, C. Uematsu\",\"doi\":\"10.1109/SICE.2002.1195314\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Some studies on inhomogeneity of type K thermocouples were reported, but inhomogeneity of each thermoelement of the thermocouples was not reported. We studied inhomogeneity of each thermoelement of T thermocouples and verified experimentally that inhomogeneity of each thermoelement can be measured by using grounded-junction sheathed thermocouples. After annealing at 400 degrees Celsius and 250 hours, the positive leg (Copper) of T thermocouples did not reveal no inhomogeneity but the negative leg(Constantan) revealed some inhomogeneity.\",\"PeriodicalId\":301855,\"journal\":{\"name\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st SICE Annual Conference. SICE 2002.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2002.1195314\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st SICE Annual Conference. SICE 2002.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2002.1195314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Inhomogeneity of each thermoelements of type T thermocouples
Some studies on inhomogeneity of type K thermocouples were reported, but inhomogeneity of each thermoelement of the thermocouples was not reported. We studied inhomogeneity of each thermoelement of T thermocouples and verified experimentally that inhomogeneity of each thermoelement can be measured by using grounded-junction sheathed thermocouples. After annealing at 400 degrees Celsius and 250 hours, the positive leg (Copper) of T thermocouples did not reveal no inhomogeneity but the negative leg(Constantan) revealed some inhomogeneity.