{"title":"基于电气测量的电力变压器风险指示器的开发和实施","authors":"Gints Poišs, S. Vītoliņa","doi":"10.1109/EPE.2017.7967289","DOIUrl":null,"url":null,"abstract":"Any failure of a power transformer can result in serious consequences for a power system. Bushing failures, mechanically damaged windings or deterioration of solid insulation may cause unexpected power line cut-offs and financial losses to a company. Faulty operation of the on-load tap changer (OLTC) caused by increased contact resistance, contact misalignment or broken drive mechanism also reduces reliability. In order to minimize risk, data obtained from various diagnostic tools needs to be interpreted to evaluate the technical condition of a particular transformer, as well as generalized to provide systematic information for asset manager. In this paper, condition indexing is used to develop a risk indicator based on the results of electrical measurements for transformer windings and core, bushings and OLTC. Also results from a case study based on data of different transformers installed in the transmission system in Latvia are provided.","PeriodicalId":201464,"journal":{"name":"2017 18th International Scientific Conference on Electric Power Engineering (EPE)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Development and implementation of risk indicator for power transformers based on electrical measurements\",\"authors\":\"Gints Poišs, S. Vītoliņa\",\"doi\":\"10.1109/EPE.2017.7967289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Any failure of a power transformer can result in serious consequences for a power system. Bushing failures, mechanically damaged windings or deterioration of solid insulation may cause unexpected power line cut-offs and financial losses to a company. Faulty operation of the on-load tap changer (OLTC) caused by increased contact resistance, contact misalignment or broken drive mechanism also reduces reliability. In order to minimize risk, data obtained from various diagnostic tools needs to be interpreted to evaluate the technical condition of a particular transformer, as well as generalized to provide systematic information for asset manager. In this paper, condition indexing is used to develop a risk indicator based on the results of electrical measurements for transformer windings and core, bushings and OLTC. Also results from a case study based on data of different transformers installed in the transmission system in Latvia are provided.\",\"PeriodicalId\":201464,\"journal\":{\"name\":\"2017 18th International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 18th International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2017.7967289\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 18th International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2017.7967289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

电力变压器的任何故障都可能导致电力系统的严重后果。套管故障,机械损坏的绕组或固体绝缘恶化可能会导致意外的电源线切断和公司的经济损失。有载分接开关(OLTC)因接触电阻增加、接触不对中或驱动机构损坏而导致的故障操作也降低了可靠性。为了最大限度地降低风险,需要对各种诊断工具获得的数据进行解释,以评估特定变压器的技术状况,并进行归纳,为资产管理者提供系统的信息。本文根据变压器绕组、铁心、套管和OLTC的电气测量结果,采用状态索引法建立了一种风险指标。本文还提供了基于拉脱维亚输电系统中安装的不同变压器数据的案例研究结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development and implementation of risk indicator for power transformers based on electrical measurements
Any failure of a power transformer can result in serious consequences for a power system. Bushing failures, mechanically damaged windings or deterioration of solid insulation may cause unexpected power line cut-offs and financial losses to a company. Faulty operation of the on-load tap changer (OLTC) caused by increased contact resistance, contact misalignment or broken drive mechanism also reduces reliability. In order to minimize risk, data obtained from various diagnostic tools needs to be interpreted to evaluate the technical condition of a particular transformer, as well as generalized to provide systematic information for asset manager. In this paper, condition indexing is used to develop a risk indicator based on the results of electrical measurements for transformer windings and core, bushings and OLTC. Also results from a case study based on data of different transformers installed in the transmission system in Latvia are provided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信